XLifter model X1, user guide, ver. 1.41, firmware ver. 0.98
Reco, spol. s.r.o., Na hlinach 6, 18200 Prague, Czech Rep., https//www.xlifter.com, [email protected]
Page 19
●
When the process is finished the display shows a message “Update successfully
finished!”
3.
Press
to exit the Service menu. The control module restart to a standard mode.
Important notice:
Do not turn off the ignition during the programming process! The control
module would lose power, the programming process would be interrupted, and
the EAS unit code would probably get corrupted (“bricked”), resulting to EAS unit
malfunction.
Emergency procedure:
Repair of the "bricked" EAS module in case of interrupted programming.
The “bricked” EAS module cannot be programmed as described above. Typical
behaviour: the control module display shows “Synchronizing” when update is
started for 1 minute and then it times out.
In this case, it is necessary to disconnect and reconnect the C connector at the EAS
unit within 1 minute since the update has started (while "Synchronizing" is
displayed). This will reset the EAS unit and programming will be restored.
Intentionally left blank