![Xinje VB3 User Manual Download Page 80](http://html1.mh-extra.com/html/xinje/vb3/vb3_user-manual_3427010080.webp)
V5 series inverter
74
20
20
20
20
:
Set running time arriving
....
When the accumulating time
(
P3.40
)
arrive the reference time (P3.39), an indication signal
will be output.
This parameter is the additional definition of No. 1 function in Table4-6. As shown in Fig.4-26, when the output frequency
of inverter is within the detecting range of reference frequency, pulse signal will be output.
Fig
Fig
Fig
Fig 4-26
4-26
4-26
4-26 Frequency
Frequency
Frequency
Frequency arriving
arriving
arriving
arriving signal
signal
signal
signal
P4.13
~
P4.14 is the additional definition of No.2 function in Fig.4-6, P4.15
~
P4.16 is the additional definition of No.3
function in Fig.4-6, The both have the same usage and the following take P4.13
~
P4.14 as an example to introduce.When
the output frequency over a certain frequency(FDT1 level), indication signal will be output until the output frequency fall to
the value which is lower than the certain frequency (FDT1 level
-
FDT1 lag)
,
as shown in Fig. 4-27.
Fig.
Fig.
Fig.
Fig.4-27
4-27
4-27
4-27
FDT
FDT
FDT
FDT level
level
level
level
Table
Table
Table
Table 4-7
4-7
4-7
4-7 Output
Output
Output
Output terminals
terminals
terminals
terminals
P4.12
P4.12
P4.12
P4.12
Detecting
Detecting
Detecting
Detecting range
range
range
range of
of
of
of frequency
frequency
frequency
frequency arrive
arrive
arrive
arrive
(
FAR
FAR
FAR
FAR
)
Range
Range
Range
Range
:
0.00
0.00
0.00
0.00
~
50.00H
50.00H
50.00H
50.00Hzzzz
5.00Hz
5.00Hz
5.00Hz
5.00Hz
P4.13
P4.13
P4.13
P4.13
FDT1
FDT1
FDT1
FDT1
(
freqeuncy
freqeuncy
freqeuncy
freqeuncy
)
level
level
level
level
Range
Range
Range
Range
:
0.00
0.00
0.00
0.00
~
upper
upper
upper
upper limit
limit
limit
limit of
of
of
of frequency
frequency
frequency
frequency
10.00Hz
10.00Hz
10.00Hz
10.00Hz
P4.14
P4.14
P4.14
P4.14
FDT1
FDT1
FDT1
FDT1 lag
lag
lag
lag
Range
Range
Range
Range
:
0.00
0.00
0.00
0.00
~
50.00H
50.00H
50.00H
50.00Hzzzz
1.00Hz
1.00Hz
1.00Hz
1.00Hz
P4.15
P4.15
P4.15
P4.15
FDT2
FDT2
FDT2
FDT2
(
frequency
frequency
frequency
frequency
)
level
level
level
level
Range
Range
Range
Range
:
0.00
0.00
0.00
0.00
~
upper
upper
upper
upper limit
limit
limit
limit of
of
of
of frequency
frequency
frequency
frequency
10.00Hz
10.00Hz
10.00Hz
10.00Hz
P4.16
P4.16
P4.16
P4.16
FDT2
FDT2
FDT2
FDT2 lag
lag
lag
lag
Range
Range
Range
Range
:
0.00
0.00
0.00
0.00
~
50.00H
50.00H
50.00H
50.00Hzzzz
1.00Hz
1.00Hz
1.00Hz
1.00Hz
P4.17
P4.17
P4.17
P4.17
Analog
Analog
Analog
Analog output
output
output
output selection
selection
selection
selection (A
(A
(A
(AO
O
O
O))))
Range
Range
Range
Range
:
0
0
0
0
~
7
7
7
7
0
0
0
0
P4.18
P4.18
P4.18
P4.18
Analog
Analog
Analog
Analog output
output
output
output gain
gain
gain
gain ((((A
A
A
AO)
O)
O)
O)
Range
Range
Range
Range
:
0.50
0.50
0.50
0.50
~
2.00
2.00
2.00
2.00
1.00
1.00
1.00
1.00
No.
No.
No.
No.
Function
Function
Function
Function
Range
Range
Range
Range
0
Output frequency
0~upper limit of frequency
1
Output current
0
-
2
×
rated current
2
Output voltage
0
-
1.2
×
rated voltage of load motor
3
Bus voltage
0
-
800V
4
PID reference
0~10V
5
PID feedback
0~10V
6
VI
0~10V
All manuals and user guides at all-guides.com