V5 series inverter
54
4-2.
4-2.
4-2.
4-2. Parameter
Parameter
Parameter
Parameter d
d
d
description
escription
escription
escription
4-2-1
4-2-1
4-2-1
4-2-1.... Basic
Basic
Basic
Basic operating
operating
operating
operating function
function
function
function parameters
parameters
parameters
parameters
(
Group
Group
Group
Group P0
P0
P0
P0
)
0
0
0
0
:
V/F
V/F
V/F
V/F control
control
control
control
1
1
1
1
:
Open
Open
Open
Open loop
loop
loop
loop vector
vector
vector
vector control
control
control
control
0
0
0
0
:
Panel
Panel
Panel
Panel analog
analog
analog
analog potentiometer
potentiometer
potentiometer
potentiometer setting
setting
setting
setting
1
1
1
1
:
and
and
and
and
keys
keys
keys
keys on
on
on
on the
the
the
the panel
panel
panel
panel
You can set the reference frequency via
and
keys on the panel.
2
2
2
2
:
Keyboard
Keyboard
Keyboard
Keyboard digital
digital
digital
digital
Initial frequency is the value of P0.02, to set the reference frequency via keyboard by modifying the value of P0.02.
3
3
3
3
:
Terminal
Terminal
Terminal
Terminal UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
Initial frequency is the value of P0.02, to set the frequency via terminal UP/DOWN.
4
4
4
4
:
Serial
Serial
Serial
Serial port
port
port
port ((((remote
remote
remote
remote control
control
control
control))))
Initial frequency is the value of P0.02, to set the frequency via serial port.
5
5
5
5
:
VI
VI
VI
VI a
a
a
analog
nalog
nalog
nalog input
input
input
input (VI
(VI
(VI
(VI
-
GND)
GND)
GND)
GND)
The reference frequency is set by analog voltage input via terminal VI, the input voltage range is DC 0~10V. The
corresponding relationship between frequency and VI is decided by parameters P1.00~P1.05.
6
6
6
6
:
CI
CI
CI
CI analog
analog
analog
analog input
input
input
input (CI
(CI
(CI
(CI
-
GND)
GND)
GND)
GND)
The reference requency is set by analog voltage/current of terminal CI and the input range is DC: 0~10V (if jumper JP3 is
placed on “V” side ), DC:4~20mA (if jumper JP3 is placed on “A” side). Then corresponding relationship between
frequency and CI input is decided by parameter P1.06~P1.10.
7
7
7
7
:
Pulse
Pulse
Pulse
Pulse input
input
input
input (PLUSE)
(PLUSE)
(PLUSE)
(PLUSE)
The referency frequency is set by pulse input via pulse terminal (can only be input via terminal X6). The corresponding
relationship between frequency and PLUSE input is decided by parameters P1.11~P1.15.
8
8
8
8
:
Combination
Combination
Combination
Combination
Please refer to P3.00
,
to set the reference frequency via combination of channels.
When the reference frequency is set in digital mode
(
P0.01
=
1,2,3,4
),
The setting of P0.02 is the inverter’s initial frequency
value.
0
0
0
0
:
Panel
Panel
Panel
Panel control
control
control
control
Input operating commands via panel start or stop the inverter by pressing
,
and
on the panel.
1
1
1
1
:
Terminal
Terminal
Terminal
Terminal control
control
control
control
Input operating commands via externals such as FWD, REV, X1~X6 to start or stop the inverter.
2
2
2
2
:
Serial
Serial
Serial
Serial port
port
port
port control
control
control
control
To start or stop the inverter via RS485 port.
Note
Note
Note
Note
:
The control modes can be controlled by modifying P0.03, while please be careful to use this method during
operating.
P0.00
P0.00
P0.00
P0.00
Control
Control
Control
Control mode
mode
mode
mode selection
selection
selection
selection
Range
Range
Range
Range
:
0
0
0
0
~
1
1
1
1
0
0
0
0
P0.01
P0.01
P0.01
P0.01
Re
Re
Re
Reference
ference
ference
ference frequnce
frequnce
frequnce
frequnce
selection
selection
selection
selection
Range
Range
Range
Range
:
1
1
1
1
~
8
8
8
8
0
0
0
0
P0.02
P0.02
P0.02
P0.02
Digital
Digital
Digital
Digital frequency
frequency
frequency
frequency setting
setting
setting
setting
Range
Range
Range
Range
:
Upper
Upper
Upper
Upper limit
limit
limit
limit of
of
of
of of
of
of
of frequncy
frequncy
frequncy
frequncy
~
lower
lower
lower
lower limit
limit
limit
limit of
of
of
of
frequency
frequency
frequency
frequency
50.00H
50.00H
50.00H
50.00Hzzzz
P0.03
P0.03
P0.03
P0.03
M
M
M
Methods
ethods
ethods
ethods of
of
of
of inputting
inputting
inputting
inputting operating
operating
operating
operating
commands
commands
commands
commands
Range
Range
Range
Range
:
0
0
0
0,,,,1
1
1
1,,,,2
2
2
2
0
0
0
0
All manuals and user guides at all-guides.com