![Xinje VB3 User Manual Download Page 63](http://html1.mh-extra.com/html/xinje/vb3/vb3_user-manual_3427010063.webp)
V5 series inverter
57
Note
Note
Note
Note
:
(1) In order to achieve better performances, the ratio of carrierfrequency to the maximum running frequency of the
inverter should be less than 36.
(2) When the carrier frequency is low, the current display value
may has error.
0
0
0
0
:
Linear
Linear
Linear
Linear Acc/Dec
Acc/Dec
Acc/Dec
Acc/Dec mode
mode
mode
mode
Output frequency increases or decreases according to a constant rate,as shown in Fig. 4-4.
1
1
1
1
:
S
S
S
S ramp
ramp
ramp
ramp Acc/Dec
Acc/Dec
Acc/Dec
Acc/Dec mode
mode
mode
mode
Output frequency increases or decreases according to a S-shape curve, as shown in Fig.4-5.
Fig.
Fig.
Fig.
Fig.4-4
4-4
4-4
4-4 Linear
Linear
Linear
Linear Acc/Dec
Acc/Dec
Acc/Dec
Acc/Dec
Fig.
Fig.
Fig.
Fig.4-5
4-5
4-5
4-5 S
S
S
S-shape
-shape
-shape
-shape curve
curve
curve
curve
P0.14 and P0.15 are only active when Acc/Dcc mode is S ramp Acc/Eec mode
(
P0.13
=
1
)
and P0.14+P0.15
<
<
<
<
90
%
.
Low speed time of S ramp is shown in Fig.4-5 as
③
, where the changing rate of output frequency increases for 0.
Linear time of S ramp is shown in Fig.4-5 as
②
, where the changing rate of output frequency is constant.
High speed time of S ramp is shown in Fig.4-5 as
①
, where the changing rate of output frequency increases from 0. High
speed time
=
100
%-
P0.14
-
P0.15.
N
N
N
Note
ote
ote
ote
:
S ramp Acc/Dec mode is suitable for the start/stop of elevator, conveying belt, conveying load and so on .
This function defines Acc/Dec time unit
0
0
0
0
:
second
second
second
second
1
1
1
1
:
minute
minute
minute
minute
Note
Note
Note
Note
:
(1) This function is active for all the process of Acc/Dec except jog running.
(2) Select second as time unit is recommended.
Acc time is the time taken for the motor to accelerate from 0 Hz to upper limit of frequency, as t
1
in Fig.4-6; Dec time is the
time taken for the motor to decelerate from upper limit of frequency to 0 Hz, as t
2
in Fig.4-6.
P0.13
P0.13
P0.13
P0.13
Acc/Dec
Acc/Dec
Acc/Dec
Acc/Dec mode
mode
mode
mode
Range
Range
Range
Range
:
0
0
0
0
、
1
1
1
1
0
0
0
0
P0.14
P0.14
P0.14
P0.14
L
L
L
Low
ow
ow
ow speed
speed
speed
speed time
time
time
time of
of
of
of S
S
S
S ramp
ramp
ramp
ramp
Range
Range
Range
Range
:
10.0
10.0
10.0
10.0
%~
50.0
50.0
50.0
50.0
%(
Acc/Dec
Acc/Dec
Acc/Dec
Acc/Dec time
time
time
time
),
P0.14
P0.14
P0.14
P0.14
+
P0.15<90
P0.15<90
P0.15<90
P0.15<90
%
20.0
20.0
20.0
20.0
%
P0.15
P0.15
P0.15
P0.15
Linear
Linear
Linear
Linear time
time
time
time of
of
of
of S
S
S
S ramp
ramp
ramp
ramp
Range
Range
Range
Range
:
10.0
10.0
10.0
10.0
%~
80.0
80.0
80.0
80.0
%(
Acc/Dec
Acc/Dec
Acc/Dec
Acc/Dec time
time
time
time
),
P0.14
P0.14
P0.14
P0.14
+
P0.15<90
P0.15<90
P0.15<90
P0.15<90
%
60.0
60.0
60.0
60.0
%
P0.16
P0.16
P0.16
P0.16
Acc/Dec
Acc/Dec
Acc/Dec
Acc/Dec time
time
time
time unit
unit
unit
unit
Range
Range
Range
Range
:
0
0
0
0,,,, 1
1
1
1
0
0
0
0
P0.17
P0.17
P0.17
P0.17
Acc
Acc
Acc
Acc time
time
time
time 1
1
1
1
Range
Range
Range
Range
:
0.1
0.1
0.1
0.1
~
6000.0
6000.0
6000.0
6000.0
10.0
10.0
10.0
10.0
P0.18
P0.18
P0.18
P0.18
Dec
Dec
Dec
Dec time
time
time
time 1
1
1
1
Range
Range
Range
Range
:
0.1
0.1
0.1
0.1
~
6000.0
6000.0
6000.0
6000.0
10.0
10.0
10.0
10.0
All manuals and user guides at all-guides.com