We can control the inverter’s START, STOP, JOG and other running actions by three command channels.
1. Operation panel
Control by
,
and
keys on the operation panel (default setting)
2. Control terminals
Use FWD, REV, COM to form 2-wire control, or use one terminal of
X1~X6 and FWD, REV to form 3-wire control.
3. Serial port
The operations such as START, STOP can be controlled by other devices which can communicate with the inverter.
You can select the command channels via parameter P0.03 or via multi-function input terminal (P4.00~ P4.07 function 23,
24).
Warning
Warning
Warning
Warning::::
The user must debug the system after changing the command channel to make sure it can meet the system
requirement, otherwise device damage and physical injury will happen.
3-1-2.
3-1-2.
3-1-2.
3-1-2. Frequenc
Frequenc
Frequenc
Frequency
y
y
y ssssetting
etting
etting
etting channel
channel
channel
channel
In common operating mode, there are 8 channels to set the frequency:
0: keyboard analog potentiometer
1:
a and
keys on the keyboard
2: Operation panel function code
3: Terminals UP/DOWN
4: Serial port
5: Analog VI
6: Analog CI
7: Pulse terminal
(
PULSE
)
8: Combination
3-1-3.
3-1-3.
3-1-3.
3-1-3. Running
Running
Running
Running state
state
state
state
There are two running state: stopping and running.
Stopping
Stopping
Stopping
Stopping state:
state:
state:
state:
After the inverter is switched on and initialized, If no operating command is executed, then the inverter
enters stopping state.
Running
Running
Running
Running state
state
state
state
:
The inverter enters running state after it receive the running command.
3-1-4.
3-1-4.
3-1-4.
3-1-4. Running
Running
Running
Running modes
modes
modes
modes
V5 inverter has 5 kinds of running modes which can be sequenced according to the priority: Jog running→Close loop
running→PLC running→Multi-step speed running→Simple running, as shown in Fig. 3-1.