V5 series inverter
47
7
7
7
7.... Fault
Fault
Fault
Fault record
record
record
recording
ing
ing
ing parameter
parameter
parameter
parameter (Group
(Group
(Group
(Group P6)
P6)
P6)
P6)
8
8
8
8.... Close-loop
Close-loop
Close-loop
Close-loop control
control
control
control parameter
parameter
parameter
parameterssss (Group
(Group
(Group
(Group P7)
P7)
P7)
P7)
P5.05
Frequeny
decrease
rate
when current limiting
0.00
~
99.99Hz/s
0.01Hz/s
10.00Hz/s
○
P5.06
Auto
current
limiting
selection
0
:
Disabled in constant speed
1
:
Enabled in constant speed
Note
:
Enabled at Acc/Dec
1
1
×
P5.07
setting of the restart after
power off
0
:
Disabled
1
:
Enabled
1
0
×
P5.08
Holding time
of
restart
after power off
0.0
~
10.0s
0.1s
0.5s
×
P5.09
Auto reset times of fault
0
~
10
0
:
No
auto
reset
function
(
Note
:
overload and
overheat have no recovery
function
)
1
0
×
P5.10
Auto reset interval of fault
0.5
~
20.0s
0.1s
5.0s
×
Group
Group
Group
Group P6
P6
P6
P6
:
Fault
Fault
Fault
Fault recording
recording
recording
recording parameter
parameter
parameter
parameter
Parameter
Parameter
Parameter
Parameter
Name
Name
Name
Name
Description
Description
Description
Description
Minmun
Minmun
Minmun
Minmun unit
unit
unit
unit
Factory
Factory
Factory
Factory
setting
setting
setting
setting
Change
Change
Change
Change
P6.00
Previous fault record
Previous fault record
1
0
*
P6.01
Output
frequency
of
previous fault
Output frequency of previous fault
record
0.01Hz
0
*
P6.02
Setting
frequency
of
previous fault
Setting frequency of previous fault
record
0.01Hz
0
*
P6.03
Output current of previous
fault
Output current of previous fault
0.1A
0
*
P6.04
Output voltage of previous
fault
Output voltage of previous fault
1V
0
*
P6.05
DC injectiong bus voltage
of previous fault
DC
injectiong
bus
voltage
of
previous fault
1V
0
*
P6.06
Module
temperature
of
previous fault
Module temperature of previous
fault
10C
0
*
P6.07
2 latest fault record
2 latest fault record
1
0
*
P6.08
3 latest fault record
3 latest fault record
1
0
*
P6.09
4 latest fault record
4 latest fault record
1
0
*
P6.10
5 latest fault record
5 latest fault record
1
0
*
P6.11
6 latest fault record
6 latest fault record
1
0
*
Group
Group
Group
Group P7
P7
P7
P7
:
Close-loop
Close-loop
Close-loop
Close-loop control
control
control
control parameter
parameter
parameter
parameterssss
Parameter
Parameter
Parameter
Parameter
Name
Name
Name
Name
Range
Range
Range
Range
Minmum
Minmum
Minmum
Minmum
unit
unit
unit
unit
Factory
Factory
Factory
Factory
setting
setting
setting
setting
Change
Change
Change
Change
P7.00
Close-loop function selection
0
:
Disabled
1
:
Enabled
1
0
×
P7.01
Reference channel selection
0
:
Digit input
1
:
VI (0~10V)
1
1
○
All manuals and user guides at all-guides.com