5/2011
2-64
Phaser 4600/4620 Printer Service Manual
12-906-00, 12-907-00, 12-910-00, 12-920-00, 12-930-00,
Revision - Xerox Internal Use Only
Status Indicator RAPS
12-906-00, 12-907-00 Jam in Mailbox Entrance RAP
12-906-00 Media did not reach the mailbox Entrance Sensor on time. Media remains in the
IOT exit.
12-907-00 Media did not clear the Mailbox entrance sensor on time.
12-908-00 Media is blocking the Mailbox Entrance Sensor.
BSD-Reference:
WD 18
Initial Actions
•
Check the Mailbox entrance sensor actuator.
•
Check for obstructions blocking the media path.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: Remove the Mailbox Rear Door (
REP 11.4
) and base plate (
PL 11.10 Item 7
) to access
the entrance sensor and actuator.
Check the condition of the Mailbox feed rollers. The feed rollers are clean and rotate freely.
Y
N
Clean or repair the affected feed rollers.
Select
dC330
code 12-905 to test the Mailbox entrance sensor. The sensor signal changes
(high/low).
Y
N
Remove the Mailbox,
GP 14
to check the condition of the Mailbox option connector,
entrance sensor and harness. The sensor is connected and the harness undamaged.
Y
N
Replace the sensor or repair the harness.
Replace the Mailbox Control Board,
REP 11.5
.
Select
dC330
code 12-120 to test the Mailbox Transport Motor,
PL 11.20 Item 1
. The motor
rotates.
Y
N
Check the Transport Motor connection and harness (
REP 11.14
). Repair or reconnect as
necessary.
Replace these components in order until the error is corrected.
1.
IOT Upper Option Harness,
PL 10.30 Item 24
2.
MCU Board,
PL 3.10 Item 3
12-910-00, 12-920-00, 12-930-00, 12-940-00 Mailbox Bin Full
12-910-00 Mailbox Bin 1 is full.
12-920-00 Mailbox Bin 2 is full.
12-930-00 Mailbox Bin 3 is full.
12-940-00 Mailbox Bin 4 is full.
BSD-Reference:
WD 18
Initial Actions
•
Check the stack full actuator of the affected output tray.
•
Reseat the Mailbox on the IOT.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: Bins (output trays) are numbered 1 through 4, 4 being the top tray.
Check the condition of the stack full actuator. The actuator moves freely and is undam-
aged.
Y
N
Clean or repair the affected actuator.
Select
dC330
code 12-910 (1), 12-920 (2), 12-930 (3), or 12-940 (4) to test the stack sensor of
the affected output tray. The sensor signal changes (high/low).
Y
N
Remove the Mailbox,
GP 14
to check the condition of the Mailbox option connector and
harness. The connector and harness are undamaged.
Y
N
Repair the harness.
Remove the Mailbox right cover and reseat P/J5 on the Mailbox Control Board. The
error message is displayed.
Y
N
Reassembly and perform
SCP 6
Final Actions.
Replace the Mailbox Control Board,
REP 11.5
.
Replace these components in order until the error is corrected.
1.
IOT Upper Option Harness,
PL 10.30 Item 24
2.
MCU Board,
PL 3.10 Item 3