REP 8.31
Repairs
Revision - Xerox Internal Use Only
REP 8.31 Registration Sensor Actuator
Parts List on
PL 8.50 Item 27
Removal
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
CAUTION
Cover the Drum Cartridge to prevent light exposure.
1.
Remove Tray 2,
2.
Remove the Toner Cartridge.
3.
Remove the Drum Cartridge.
4.
Remove the Duplex Unit,
REP 10.1
.
5.
Remove the IP Board Cover,
REP 28.1
.
6.
Remove the Right Cover,
REP 28.2
.
7.
Remove the Registration Clutch,
REP 4.3
.
8.
Remove the Registration Roller Assembly,
REP 8.27
.
9.
Remove 2 screws (plastic) that secure the envelope guide to the frame,
Figure 1
.
Figure 1 Remove the envelope guide screws
10. Release 2 clips that secure the actuator cap to the frame and remove the cap,
Figure 2
.