Status Indicator RAPS
12-605-00 Staples Low RAP
12-605-00 The Staple Cartridge is near empty as indicated by the low staple sensor in the Sta-
pler.
BSD-Reference:
WD 17
Initial Actions
•
Reseat the Staple Cartridge.
•
Replace the Staple Cartridge.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: Remove the Stacker Shield Assembly,
REP 12.24
to access the Stapler harness.
Cycle system power. The error message is displayed.
Y
N
Perform
SCP 6
Final Actions.
Select
dC330
code 12-860 to test the low staple sensor. The sensor signal changes (high/
low) as the staple cartridge is installed or removed.
Y
N
Remove the Finisher,
GP 14
to check the condition of the Finisher option connector and
harness. The connector and harness are undamaged.
Y
N
Replace the sensor or repair the harness.
Check Stapler harness connections. The sensor is connected and the harness
undamaged.
Y
N
Repair or reconnect the harness.
Replace the Stapler,
REP 12.14
. The error message is displayed.
Y
N
Reassembly and perform
SCP 6
Final Actions.
Replace the Finisher Control Board,
REP 12.2
.
Replace these components in order until the error is corrected.
1.
IOT Upper Option Harness,
PL 10.30 Item 24
2.
MCU Board,
PL 3.10 Item 3
12-610-00, 12-855-00 Out of Staples RAP
12-610-00 The Stapler Cartridge is empty as indicated by the Stapler self priming sensor.
12-855-00 The Stapler is not properly primed with staples as reported by the self priming sen-
sor.
BSD-Reference:
WD 17
Initial Actions
•
Reseat the Staple Cartridge.
•
Replace the Staple Cartridge.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: Remove the Stacker Shield Assembly,
REP 12.24
to access the Stapler harness.
Cycle system power. The error message is displayed.
Y
N
Perform
SCP 6
Final Actions.
Select
dC330
code 12-855 to test the self priming sensor. The sensor signal changes as the
staple cartridge is installed or removed.
Y
N
Remove the Finisher,
GP 14
to check the condition of the Finisher option connector and
harness. The connector and harness are undamaged.
Y
N
Replace the sensor or repair the harness.
Check Stapler harness connections. The sensor is connected and the harness
undamaged.
Y
N
Repair or reconnect the harness.
Replace the Stapler,
REP 12.14
. The error message is displayed.
Y
N
Reassembly and perform
SCP 6
Final Actions.
Replace the Finisher Control Board,
REP 12.2
.
Replace these components in order until the error is corrected.
1.
IOT Upper Option Harness,
PL 10.30 Item 24
2.
MCU Board,
PL 3.10 Item 3