2-34
Phaser 3300MFP Service Manual
Theory of Operation
Fusing
The temperature change of the heat roller’s surface varies with the resistance
value through the thermistor. The resistance value determines how much
voltage will be converted into heat to raise the temperature of the fuser. If the
value measured by the thermistor is out of controlling range, one of the errors
below may occur:
Open Heat Error
This error occurs when a specified temperature is not reached during the
warm up process. When this happens, the engine stops all functions and
processes. The engine then informs the error status to the main system. An
error message is then displayed on the LCD which informs the user.
Recovery is performed automatically. Maximum heat is supplied to the fuser
and a second reading is taken. When the specified temperature is reached,
the printer resumes operation as normal.
Low Heat Error
This error occurs when the temperature is lower than the specified
temperature during stand-by, printing or warm-up mode. When this happens,
the engine stops all functions and processes. The engine then reports the
error status to the main system. An error message is then displayed on the
LCD which informs the user.
Recovery is performed automatically. Maximum heat is supplied to the fuser
and a second reading is taken. When the specified temperature is reached,
the printer resumes operation as normal.
Over Heat Error
This error occurs whenever the printer temperature is higher than specified.
When this happens, the engine stops all functions and processes. The engine
then informs the error status to the main system. An error message is then
displayed on the LCD or LED which informs the user.
Recovery is performed automatically. The heat supply is cut off to the fuser
and a second reading is taken. When the temperature is a degree below the
specified temperature, printer resumes operation as normal.
Error
Temperature Control Concept
Open Heat Error
90 °C below for 45 sec at Warm up
Over Heat Error
230 °C over for 10 sec or 240 over for 5 sec
Low Heat Error
Standby: 130 °C below for 10 sec
Printing: 35 °C below for 7 sec at consecutive 2 page printing.
Summary of Contents for Phaser 3300
Page 1: ...Phaser 3300MFP Multi Function Printer Phaser 3300MFP Service Manual...
Page 2: ......
Page 16: ...xiv Phaser 3300MFP Service Manual...
Page 81: ...3 Chapter Error Messages and Codes In this chapter Introduction Jam Error Codes Error Messages...
Page 92: ...3 12 Phaser 3300MFP Service Manual Error Messages and Codes...
Page 118: ...4 26 Phaser 3300MFP Service Manual General Troubleshooting...
Page 136: ...5 18 Phaser 3300MFP Service Manual Print Quality Troubleshooting...
Page 140: ...6 4 Phaser 3300MFP Service Manual Adjustments and Calibrations...
Page 272: ...9 38 Phaser 3300MFP Service Manual Parts List...
Page 288: ...10 16 Phaser 3300MFP Service Manual Wiring Diagrams...
Page 289: ...A Appendix Appendix Contents Phaser 3300MFP Menu Map Acronyms and Abbreviations...
Page 295: ......