Installation Planning Guide
6- 5
Printer requirements and specifications
Environmental specifications
When you select a location for your printer, avoid environments
with extreme variations in temperature and other hazards, such as
excessive dust or humidity. Recommended environmental ranges
for the work area are as follows:
Table 6-5 Printer environmental specifications
Space requirements
You should consider the following factors when deciding where to
place the printer hardware components:
•
Adequate work space and service clearance around the
equipment
Condition
Range
Operating
temperature
Recommended:
Minimum:
Maximum:
68° F to 76° F / 20° C to 24° C
50° F / 10° C
85° F / 29° C
Humidity
Recommended:
Minimum:
Maximum:
45% ±10%
30%
65%
Altitude:
Normal:
Maximum:
Up to 6,000 feet / 1,830 m
above sea level
9,000 feet / 2,743 m above
sea level
Heat
dissipation:
DP 155 and
180 (2-stacker
system)
DP 100, 115,
and 135
(2-stacker
system)
Operating:
Standby:
Energy Saver:
Operating:
Standby:
Energy Saver:
32,770 BTU/hour
4,454 BTU/hour
2,700 BTU/hour
28,140 BTU/hour
4,454 BTU/hour
2,700 BTU/hour
Audible noise
Operating:
Continuous:
Impulse:
Standby:
Continuous:
Impulse:
82 dB(A)
82 dB(A)
52 dB(A)
N/A
Summary of Contents for Nuvera 100
Page 1: ...installation Xerox DocuPrint 100 115 135 155 180 EPS 701P24750 April 2005 guide planning...
Page 6: ...iv Installation Planning Guide Table of contents...
Page 16: ...xiv Installation Planning Guide Introduction...
Page 76: ...6 28 Installation Planning Guide Printer requirements and specifications...
Page 77: ...Installation Planning Guide 6 29 Printer requirements and specifications...
Page 78: ...6 30 Installation Planning Guide Printer requirements and specifications...
Page 79: ...Installation Planning Guide 6 31 Printer requirements and specifications...
Page 80: ...6 32 Installation Planning Guide Printer requirements and specifications...
Page 82: ...6 34 Installation Planning Guide Printer requirements and specifications...
Page 86: ...7 4 Installation Planning Guide System connections...