Maintenance & Troubleshooting
WorkCentre Pro 412, FaxCentre F12 &
3/03
7-17
WorkCentre M15/M15i
Abnormal Image Printing and Defective Roller
If abnormal image prints periodically, check the parts shown below.
Horizontal band
1. Unstable high voltage contact
2. Charge roller’s contamination
3. Contamination of heat roller
4. Malfunction of LSU
1. Clean each contact and check good con-
tact
2. Clean charge roller
3. Replace fuser unit
4. Check Main PBA.
NO
Roller
Abnormal image period
Kind of abnormal image
1
OPC Drum
94.3 mm
White spot. Black spot
2
Charge Roller
37.7 mm
White spot. Black spot
3
Supply Roller
35.8 mm
Horizontal dark band
4
Developer Roller
44.8 mm
Horizontal dark band
5
Transfer Roller
57.8 mm
Black side contamination/transfer fault
6
Heat Roller
82.5 mm
Black spot, White spot
7
Pressure Roller
78.5 mm
Black side contamination
Error Status
Check
Solution
Summary of Contents for FaxCentre F12
Page 8: ...Table of Contents TOC 6 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Page 44: ...Circuit Description 5 6 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Page 45: ...Circuit Description WorkCentre Pro 412 FaxCentre F12 3 03 5 7 WorkCentre M15 M15i ...
Page 46: ...Circuit Description 5 8 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Page 47: ...Circuit Description WorkCentre Pro 412 FaxCentre F12 3 03 5 9 WorkCentre M15 M15i ...
Page 48: ...Circuit Description 5 10 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Page 49: ...Circuit Description WorkCentre Pro 412 FaxCentre F12 3 03 5 11 WorkCentre M15 M15i ...
Page 50: ...Circuit Description 5 12 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Page 170: ...Disassembly and Reassembly 6 58 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Page 380: ...XEROX EUROPE ...