A-14 975-0200-01-01
S
C
PI
C
o
mm
an
d
R
e
fe
re
n
ce
SCPI Command Summary
The SCPI commands supported by this programmable power supply are described in the
tables in the remainder of this section. These tables use the following column headings:
•
Function
The commonly used name for the function.
•
SCPI Command
The full command in long form.
•
Description
Explains what the command does or what is affected by it.
•
Query?
Indicates whether the unit supports a query version of the listed command.
N/A
indicates
Not applicable. (The command has no query form and will respond with an error
if queried.)
Table A-1
IEEE 488.2 Commands
Function
SCPI Command
Description
Parameter and
Range
Query
Select
Address
*ADR
Select the power supply unit
to communicate with.
?|<Address (1–30)>
Yes
Clear Status
*CLS
[:]STATus[<channel>]:CLEAr
Clears all the status data
structures.
N/A
Query the
Error Queue
*ERR
Query the Error Queue for
the oldest error event.
Standard
Event Status
Enable Query
*ESE?
[:]STATus[<channel>]:STANdard:ENABle
Query the Standard Event
Status Enable register
settings.
Yes
Standard
Event Status
Enable
*ESE
[:]STATus[<channel>]:STANdard:ENABle
<ESE-word>
Set the Standard Event
Status Enable Register bits.
<Enable Flags(0–
255)>
N/A
Standard
Event Status
Register
Query
*ESR?
[:]STATus[<channel>]:STANDard[:EVENt]?
Query the Standard Event
Status Register (SERS).
Yes
Summary of Contents for XTR6-110, XTR8-100, XTR12-70,
Page 2: ......
Page 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Page 6: ......
Page 18: ...xvi...
Page 48: ...2 18...
Page 122: ...4 30...
Page 208: ...6 20...
Page 244: ...A 36...
Page 250: ...B 6...
Page 264: ...C 14...
Page 272: ...IX 4...
Page 273: ......