Local Operation
3-8
975-0200-01-01
Display Messages on the Front Panel
The front panel displays on the power supply will use text as shown in
Table 3-2 to indicate the status or mode.
Table 3-2
Front Panel Display Text
Display Text
Text Description
0
Negative Polarity
232
RS 232
485
RS 485
8888
All segments On, Power Up
|
Positive Polarity
AC
Alternating Current
ADDr
RS 485 Address
ANPR
Analog Programming
AS
Power On Autostart
AvAS
Auxiliary Autostart
BP5
Data rate (BPS)
CAPr
Current Analog Programming
CLr
Clear
CC
Constant Current
CU
Constant Voltage
CrPC
Coarse Current Pre-set Mode
CrPU
Coarse Voltage Pre-set Mode
CUrr
Current
deLa
Fold Delay
done
Done
Err
Error (debug)
F0LD
Foldback
FAIL
Fail
FAn
Fan
FLA
Flash
FnpC
Fine Current Preset Mode
FnPU
Fine Voltage Preset Mode
FLd
Foldback
GPIB
GPIB Interface
In
Interlock
LAn
ENET Interface
LE C
Current APG Level
Summary of Contents for XTR6-110, XTR8-100, XTR12-70,
Page 2: ......
Page 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Page 6: ......
Page 18: ...xvi...
Page 48: ...2 18...
Page 122: ...4 30...
Page 208: ...6 20...
Page 244: ...A 36...
Page 250: ...B 6...
Page 264: ...C 14...
Page 272: ...IX 4...
Page 273: ......