![Xantrex XTR6-110, XTR8-100, XTR12-70, Operating Manual Download Page 137](http://html1.mh-extra.com/html/xantrex/xtr6-110-xtr8-100-xtr12-70/xtr6-110-xtr8-100-xtr12-70_operating-manual_3451832137.webp)
Hardware and Connection Setup
975-0200-01-01
5-15
5
Multiple Power Supply Connections to RS-485 Bus
Up to 30 units may be connected to the RS-485 bus. The first unit (master
unit) connects to the controller via any appropriate port, and the other
units (slave units) are connected with the RS-485 bus via the J6
connector. All units connected together should also have unique
multichannel addresses.
A standard straight-through RJ-45 ethernet network cable can be used to
provide the connection between the power supplies. See Figure 5-14.
Multiple Power Supply Setup
Master Setup:
u
Configure the master XTR by selecting the communication interface
you wish to use to communication with the Master and follow the
setup instruction in this chapter.
Slave Setup:
1. Turn the mode control knob to PGM.
rE
is displayed in the output voltage display.
Figure 5-14
Multi Power Supply Connection to RS-485 Bus
Note:
If either RS-232 or RS-485 are used for communication with the
master, the data rate must be configured for 9600 bps to properly communicate
with the slave units.
Summary of Contents for XTR6-110, XTR8-100, XTR12-70,
Page 2: ......
Page 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Page 6: ......
Page 18: ...xvi...
Page 48: ...2 18...
Page 122: ...4 30...
Page 208: ...6 20...
Page 244: ...A 36...
Page 250: ...B 6...
Page 264: ...C 14...
Page 272: ...IX 4...
Page 273: ......