background image

MODEL 

X-OVEN.2

NÁVOD PRO INSTALACI, 

POUŽITÍ A ÚDRŽBU

Pouze pro potøebu zákazníkù 

Summary of Contents for X-OVEN.2

Page 1: ...MODEL X OVEN 2 N VOD PRO INSTALACI POU IT A DR BU Pouze pro pot ebu z kazn k...

Page 2: ...Extractor hood requirements 13 Movement and positioning 13 Image 7 Wheels and adjustable feet 13 Image 8 Centering the bubble 14 Installation under extractor hood 14 Image 9 Correct positioning exampl...

Page 3: ...wers 31 Image 20 Grill drawer removal 31 Fire breaker s net filter 31 Image 21 Fire breaker s net filter removal 31 Grill drawer s telescopic guides 31 Image 22 Telescopic guides release 31 Image 23 T...

Page 4: ...r Authorized sales channel can be used visit www x oven com The X Oven 2 is covered by a two year warranty starting from the delivery date except for those parts that are subject to fair wear and tear...

Page 5: ...identification data X Oven International Sagl Via Cantonale 11 6900 Lugano CH Tel 41 91 921 2882 Fax 41 91 921 2883 mail info x oven com www x oven com VAT number CHE 304 402 623 IVA Business registry...

Page 6: ...ding handles 840 mm Depth with front hatch opened 1240 mm Total height with wheels on ground smoke outlet valve and fire breaker 1668 mm Height X Oven 2 802 mm Height brazier lifting cart 566 mm Heigh...

Page 7: ...and have not suffered damages during transportation If any faults or damages are present the Customer is responsible to promptly inform the Manufacturer and or the Authorized sales channel see Custome...

Page 8: ...utlet valve Warmer grill X Oven 2 Grill drawers Brazier lifting cart Stainless steel grills 1 1 Grease drainer plate Grease drainer tray Grease drainer support Grease drainer support holder Brazier tr...

Page 9: ...ing cart The Customer be fore installing and using the product is responsible for completing the assem bly of the following parts Insert the Smoke outlet valve into the smoke outflow opening on top of...

Page 10: ...drainer assembly Secure the Grease drainer on the lower lateral cover panel on the side the Grill drawers open utilizing the screw caps and the Grease drainer support holder see Image 5 Position the...

Page 11: ...11 X Oven 2 January 2017 Image 6 Completed assembly Check that the assembly of the X Oven 2 model is performed correctly see Image 6...

Page 12: ...ce the product under an extractor hood The product can be also used outdoor obtaining the same performances declared and cooking result Safety distances In an indoor environment the X Oven 2 must be p...

Page 13: ...mensions 90 x 120 cm The Manufacturer is not responsible for the installations use and maintenance of the extractor hood and or exhaust pipe The Manufacturer is relieved from any responsibilities in t...

Page 14: ...can be discharged directly into the extractor hood if safety distances see Chart 3 and the extractor hood requirements see Chart 4 are satisfied Below find examples of the correct front and side view...

Page 15: ...old inside the product any potentially incandescent particles The temperature of the combustion fumes at the extractor hood intake has been measured by an independent specialized technician that has v...

Page 16: ...of the X Oven 2 under an extractor hood see Chart 4 and connected directly to an exhaust pipe is possible with the use of the Exhaust pipe connector The device is optionally supplied visit www x oven...

Page 17: ...ct is installed and used Outdoor installation The installation of the X Oven 2 outdoor is possible with the use of the optional accessories Exhaust pipe connector and Outdoor pipe visit www x oven com...

Page 18: ...uct it is necessary to set up a solid support base appropriate to withstand the weight of the product and to guarantee leveling The product should be positioned in a wind protected location in order n...

Page 19: ...ends keeping the space under the Grease drainer and next to the Air inlet valve free from any object that might clog or obstruct the air flow Test First ignition The Manufacturer informs the Customer...

Page 20: ...ines the importance of the charcoal choice to reach the performances declared and guarantee an effective use and service The Client is free to utilize his own selection of charcoal being aware that th...

Page 21: ...Oven 2 January 2017 Ignition Find below the illustrated and described instructions for properly igniting the X Oven 2 Open the Air inlet valve Open the Smoke outlet valve Turn on the extractor hood On...

Page 22: ...ements posi tioned on the interior side walls 1st Level 4 Kg 2nd Level 6 kg while the third is the upper edge of the Brazier tray 8 Kg The operator must load the Brazier tray with the sug gested amoun...

Page 23: ...position them in the center of the brazier tray and ignite them Open the lower Grill drawer to avoid that the flames possibly damage the grill or the telescopic guides For a proper ignition of the cha...

Page 24: ...quently faster the charcoal consumption The Manufacturer advises to keep the Air inlet valve closed during service This way the brazier will receive air primarily when the Grill drawers are opened and...

Page 25: ...see Image 15 During service if charcoal consumption makes it necessary it s possible to move the Brazier tray closer to the Grill drawers to maintain a stable heat level During service it is possible...

Page 26: ...ified with the use of X Oven s charcoal see Charcoal The use of a different charcoal could considerably influence the performances of the product the amount of charcoal to be used and the duration of...

Page 27: ...e both for simultaneous cooking of different food and for the preparation of particularly greasy ali ments As a thumb rule the Manufacturer advises to use the Grill drawer 1 for cooking food rapidly a...

Page 28: ...minate the food being prepared The Manufacturer informs that it is not advisable to touch the surface of the cover panels during service in order to prevent burns The operator can safely use the handl...

Page 29: ...ntees a gradual and safe extinguishing of the charcoal The ashes must be removed before igniting the product for the next service This operation must be done when the product is shut down and cold usi...

Page 30: ...includes a chart summarizing all the maintenance and cleaning operation to perform to keep the product properly functional and efficient to cook food in a clean environment and in a healthy way The C...

Page 31: ...mage 21 Fire breaker s net filter removal Grill drawers The Grill drawers can be easily removed from the product see Image 20 It s necessary to lift the front part of the Grill drawer in order to free...

Page 32: ...guides snap fit Remove the telescopic guide from the snap fit system see Image 23 Grease drainer plate and tray removal The plate and tray of the Grease drainer can be removed for cleaning see Image 2...

Page 33: ...razier lifting cart do not conduct heat and allow the operator to work without employing any particular protection Open the Front hatch with caution during service as sudden supply of oxy gen to the e...

Page 34: ...ered that could affect the proper and safe use of the product to immediately stop its use to promptly inform the Manufacturer and or the Authorized sales channel and request technical assistance ident...

Page 35: ...safety measures Also all the specific safety measures in regards to the Product have been taken into consideration and have been verified by the same Notified Entity who has issued a certificate of a...

Page 36: ...lean Sponge Degreaser Fire breaker WEEKLY Remove and clean Dishwasher Detergent Sanitizer Fire breaker s net filter DAILY Remove and clean Brush Dishwasher Detergent Sanitizer Smoke outlet valve WEEKL...

Page 37: ...Professional oven fired by solid fuel 5 Harmonized standard EN 12815 2001 A1 2004 AC 2007 6 Notified Body Carried out Istituto Di Ricerche E Collaudi M Masini Srl Notified Body n 0068 Initial type ap...

Page 38: ...SO2 Nm3 40 Oxygen O2 v v 16 5 Carbon Dioxide CO2 v v 4 6 1 Standardised volumes and flow rates are referred to a temperature of 273 K and a pressure of 101 323 kPa 2 The concentrations of pollutants...

Reviews: