- Gaseous emission temperatures test report
DETERMINATION OF FLUID DYNAMIC AND COMBUSTION PARAMETERS
RESULTS OF ANALYSES
Determined parameters
Unit of measurement
Measured values
Test method
Average gas flue temperature
Average gas flue temperature
Cross-section of the circular conduit
°C
°K
m
2
223
496
0.0113
UNI EN ISO 16911-1
Emission speed rate
Actual hourly flow rate
Hourly flow rate on normal conditions
m / s
m
3
/ h
Nm
3
/ h
1.1
44.7 ± 5%
24.6 ± 5%
Combustion efficiency
Air in excess
%
///
65
3.1
Determined parameters
Unit of measurement
Obtained values
Test method
Volatile organic compounds (VOC)
mg C / Nm
3
96
UNI EN 12619
Total Nitrogen Oxides (NO
x
)
mg NO
2
/ Nm
3
59
ASTM D6522
Carbon Oxide (CO)
mg CO / Nm
3
> 2500
Total Sulphur Oxides (SO
x
)
mg SO
2
/ Nm
3
40
Oxygen (O
2
)
% v/v
16.5
Carbon Dioxide (CO
2
)
% v/v
4.6
1) Standardised volumes and flow rates are referred to a temperature of 273°K and a pressure of 101.323 kPa.
2) The concentrations of pollutants are referred to a theoretical oxygen content equal to 13% viv.
3) The measurements, samplings and subsequent lab analyses have been carried out by means of instruments
calibrated according to acknowledged or primary standards of reference.
4) The lab management is ready to supply further explanations about the calculation methods of measurement
uncertainly combined with the results expressed.
5) The results represent the average values of all instrumental tests performed on the field.
Distance between the oven
outlet and the hood
Measured
temperature
15 cm
125°C
25 cm
76°C
30 cm
71°C
35 cm
68°C
40 cm
63°C
45 cm
55°C
50 cm
55°C
55 cm
55°C
Moreover, it is made known that the gas flue temperature
measured at the outlet of the charcoal supplied oven is 220°C.