WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-II
⇐
Response
: Request
received, send data now
02 44 01 00 00 47
⇐
Indication
: Received
string "
ABCD
" from
0x11 0x00
0x00 0xDA 0x18 0x00
with RSSI of 0xCA
(-54dBm)
02 84 0B 00
11 00
00 DA 18 00
CA
41
42 43 44
90
⇐
Response
: Data
transmitted successfully
02 C4 01 00 00 C7
6. Reply with "EFGH" to module B.
Info
Module A
Module B
⇒
Request
: Send "
EFGH
"
to module B
02 04 04 00
45 46 47
48
0E
⇐
Response
: Request
received, send data now
02 44 01 00 00 47
⇐
Indication
: Received
string "
EFGH
" from
0x55 0x00
0x00 0xDA 0x18 0x00
with RSSI of 0xC1
(-63dBm)
02 84 0B 00
55 00
00 DA 18 00
C1
45
46 47 48
D7
⇐
Response
: Data
transmitted successfully
02 C4 01 00 00 C7
7. Now module A closes the connection, so both modules will get a disconnect indication.
Info
Module A
Module B
⇒
Request
Disconnect
02 07 00 00 05
⇐
Response
Request received, disconnect now
02 47 01 00 00 44
⇐
Indication
Connection closed
02 87 01 00 16 92
⇐
Indication
Connection closed
02 87 01 00 13 97
8. You may want to perform a
to restore default settings.
5.6.1.3. Bonding
The
SECFLAGS_BONDING_ENABLE
flag in the
user setting allows enabling the bond-
ing feature. This feature stores the keys that are exchanged during the pairing phase in a
connection setup. With this, subsequent connections to bonded devices can be established
without renegotiation. Bonding data of up to 32 devices will be stored in the flash.
Order code 2608011x24010
42
Version 1.11 , July 2022