WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-II
Info
Module A
Module B
⇒
Request
: Send "
EFGH
"
to module B
02 04 04 00
45 46 47
48
0E
⇐
Response
: Request
received, send data now
02 44 01 00 00 47
⇐
Indication
: Received
string "
EFGH
" from
0x55 0x00
0x00 0xDA 0x18 0x00
with RSSI of 0xC1
(-63dBm)
02 84 0B 00
55 00
00 DA 18 00
C1
45
46 47 48
D7
⇐
Response
: Data
transmitted successfully
02 C4 01 00 00 C7
7. Now module A closes the connection, so both modules will get a disconnect indication.
Info
Module A
Module B
⇒
Request
Disconnect
02 07 00 00 05
⇐
Response
Request received, disconnect now
02 47 01 00 00 44
⇐
Indication
Connection closed
02 87 01 00 16 92
⇐
Indication
Connection closed
02 87 01 00 13 97
8. You may want to perform a
to restore default settings.
5.6.1.2. StaticPasskey mode
In case of the "StaticPasskey" mode, a pass key has to be entered at the central side that has to
match the pass key of the peripheral. Here the Proteus-II uses a static pass key in the periph-
eral role that is stored in the parameter
. When using this method, the central
device requests its host to enter the correct pass key (see
). In this case the
pass key of the peripheral has to be entered on central side using the
com-
mand. If the entered pass key is correct, the channel will be opened for data transmission.
Otherwise, the connection will be rejected.
Example: Secured connection with security method "StaticPasskey"
1. Power-up the modules and make their UARTs accessible by the host(s) (115200 Baud,
8n1). After the power-up or after reset the following sequence is sent from the module
Order code 2608011x24010
39
Version 1.11 , July 2022