WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-II
0x00:
Request received, will perform factory reset now
0x01:
Operation failed
0xFF:
Operation not permitted
To save the parameters in the flash memory of the module, the particular mem-
ory segment must first be flushed entirely and then restored from RAM. If a
reset occurs during this procedure (e.g. due to supply voltage fluctuations), the
entire memory area may be destroyed.
During start-up of the device, the user settings memory is checked for consis-
tency. In case of inconsistency (e.g. the memory was erased) the device will
perform a factory reset.
This command also removes all bonding data.
7.5.6. CMD_UARTDISABLE_REQ
This command disables the UART of the module. It will be re-enabled when the module has to
send data to the host (e.g. data was received via RF or a state is indicated) or if the
pin is used (apply a falling edge, hold low for at least 10ms before applying a rising edge
and hold high for at least 10ms). In this case, either the received data or a
is transmitted by the module. Afterwards the UART will stay active until another
or
or a timer triggered sleep event occurs.
Format:
Start signal
Command
Length
CS
0x02
0x1B
0x00 0x00
0x19
Response (
Start signal
Command | 0x40
Length
Status
CS
0x02
0x5B
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request received, will disable UART now
0x01:
Operation failed
0xFF:
Operation not permitted
Order code 2608011x24010
74