WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-II
0x00:
DTM reset (note: this command does not perform a module reset.
0x01:
Start RX test
0x02:
Start TX test
0x03:
Stop last test
Payload:
0x00:
Bit pattern PRBS9
0x01:
Bit pattern 0x0F
0x02:
Bit pattern 0x55
0x03:
Vendor specific
Payload
6
=
Vendor specific (0x00, 0x01 or
0x02)
Payload = Vendor specific (0x03)
Length / Vendor Command:
Length / Vendor Command:
Length of the packet to send
0x00: Carrier test
0x02: Set transmission power
Channel:
Vendor option:
Frequency = (2402 + Channel * 2) MHz to
be used for RX/TX
(dependent on used "Vendor command")
Frequency = (2402 + [Vendor option] * 2)
MHz
or
[Vendor option] := TXPower (in two’s
complement notation) in steps of 4 dB
Response (
Start signal
Command | 0x40
Length
Status
Result
CS
0x02
0x5E
2 Bytes
1 Byte
0-2 Bytes
1 Byte
Status:
0x00:
Request received
0x01:
Operation failed
0x03:
Busy
0xFF:
Operation not permitted
Result:
Order code 2608011x24010
78