WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-II
8.8. RF_SecFlags: Modify the security settings
Settings
index
Designation
Permissible
values
Default value
Permissions
Number
of
Bytes
12
See
description
0
read/write
1
This 8-Bit field configures security settings of the module. Chapter
contains further infor-
mation about secure connections.
When connecting from a Proteus-II to another Proteus-II, be sure that the same
security mode is used.
When connecting from a foreign device to a Proteus-II, the peripheral (Proteus-
II) determines the minimum security level needed for communication. So con-
figure the
of the peripheral to set the desired security level.
When updating this user setting (like enabling bonding or changing the se-
curity mode) please remove all existing bonding data using the command
Order code 2608011x24010
95