3
15
Interface description:
L1-L32 or L01-L32, are exterior lines 1 to 32.
E1~E256 or E001-E256, are extension lines 1~256.
Default extension number is 8000 to 8255.
ACR interface is computer operator input interface (3.5mm audio socket).
SPT interface is HD broadcast interface, connects to the input interface of
broadcast system.
PC interface is a network management interface, connects to the LAN of router
or network switch.
RS232 interface for the serial management interface, connects to the computer
RS232 serial port, K416S only support RS232 interface.
11D and 9D, "RS232" and "PC" are two choices, change the switch on the main
board to select one of that. If the network module is installed at the factory, the
"RS232" serial port cannot be used.
SYS is the system working led, slow flash when idle, quick flash when using
extension or exterior line.
It is recommended to use pure copper telephone wires with wires of 0.5 or above,
and avoid parallel wiring with power lines and other high-frequency lines. If the
condition is limited, must add isolation or line distance of more than one meter,
to prevent noise interference.
The PBX is recommended to be installed in the machine room, which should be
dry, ventilated, free from corrosive gas, strong electric interference, strong
mechanical vibration and dustproof.
Sufficient space should be reserved around the PBX for installation, debugging,
maintenance and heat dissipation.