5.
OPERATION AND PARAMETERS DESCRIPTION
5.1.
Overview
Three interfaces are available to set the transmitter:
•
The front panel menus for local configuration
–
see chapter 6
•
The serial/Telnet commands for local or remote configuration
–
see chapter 7
•
The embedded web site for remote configuration
–
see chapter 8
In all cases, the parameters are the same and they are described below.
Remote configuration can only be done if the transmitter is fitted with a TCP/IP board.
5.2.
Local mode
The local mode is used for maintenance operations. It allows the technician to make sure nobody nor any system will
control the transmitter during the operation.
Enable/Disable the local mode
•
With the front panel local button. The lit yellow LED indicates the unit is in local mode; it is in remote mode
when the LED is off.
•
With a serial command: TX.MODE=LOCAL or REMOTE.
o
Modification of the configuration with local interfaces
In local mode, the transmitter can be modified using the front panel application (see chapter 6) or with serial
commands (see chapter 7).
Disabling remote control interfaces
In local mode, updates with the web site are not accessible.
If the module is equipped with the GPIO option, in local mode, inputs and outputs are disabled until the transmitter is
no longer in local mode (see chapter 10).
Signal suppression mode
T
he SNMP includes a “signal suppression” function which works in local mode and makes it possible to not transmit
traps associated with maintenance operations (see section 8.7.8 for more details).