![Worldcast Systems ECRESO FM 10kW User Manual Download Page 210](http://html1.mh-extra.com/html/worldcast-systems/ecreso-fm-10kw/ecreso-fm-10kw_user-manual_997884210.webp)
ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 210
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
When changing the time scale using the hour / day / week / month buttons, the selected time remains centered in the
display frame.
You can slide the date tag to display the compound value at a given time.
Return to the main view by clicking
.
Curves are refreshed once per hour.
In the main table, various parameters and alarms are displayed. The list and range of possible values vary depending
on the transmitter power:
5 kW
10 kW
1 dB Threshold *
X
X
10 MHz switch
X
X
3 dB Threshold *
X
X
Ambient temperature *
-20 - +80°C
-20 - +80°C
Atmospheric Pressure
0
–
2000 hPa
0
–
2000 hPa
Auxiliary Power supply
X
X
Main Control Board Temperature
0 - 125°C
0 - 125°C
Main Control Board Temperature alarm
Threshold: 65°C
Threshold: 65°C
Current Power Supply Output
0 - 420 A
0 - 420 A
Digital Modulator 1/2 Temperature
0 - 125°C
0 - 125°C
Digital Modulator 1/2 Temperature alarm
Threshold: 65°C
Threshold: 65°C
Fan1 speed *
0 - 15000 rpm
0 - 15000 rpm
Fan2 speed *
0 - 15000 rpm
0 - 15000 rpm
Fan3 speed *
0 - 15000 rpm
0 - 15000 rpm
Fan4 speed *
0 - 15000 rpm
0 - 15000 rpm
Heatsink Temperature (Power Amplifier) *
-20 - 100°C
-20 - 100°C
Heatsink Temperature (Power Supply) *
-20 - 100°C
-20 - 100°C
Input Switch
X
X
Interlock missing
X
X
Local mode
X
X
Low battery
X
X
Operation mode
X
X
PLL lock
X
X
Power Supply Temperature
0 - 100°C
0 - 100°C
Drive Power
0
–
120 W
0
–
120 W
RDS switch
X
X
RF not present
X
X
SD card logging
X
X
Standby
X
X
Transmitter Fault
X
X
Transmitter Warning
X
X
Voltage RF Switch Power Supply (+24V)
0
–
28 V
0
–
28 V
Voltage Control Unit Power Supply (+12V)
0
–
14 V
0
–
14 V