www.worldcastsystems.com
–
RF OFF
RM5
REL__RF_OFF_R(21)
REL_RF_OFF_COM(4)
Numbers in parenthesis indicated the pin number on the DB25 connector.
Jumper positions:
Jumper
Function
Default
position
Result
Alternative
J11
REL1 - REMOTE
2-3
REPOS
1-2 : NC
J14
REL3 - STANDBY
2-3
REPOS
1-2 : NC
J15
REL4 - WARNING
1-2
TRAVAIL
2-3 : NO
J17
REL5 - FAULT
2-3
TRAVAIL
1-2 : NO
J2
Statut - Commun
1-2
V+
2-3 : NO
J9
REMOTE_COM
2-3
MASSE
1-2 : rel_remote_com
J10
RF_OFF_COM
2-3
MASSE
1-2 : rel_rf_off_com
J16
FAULT_COM
2-3
MASSE
1-2 : rel_fault_com
J12
STANDBY_COM
2-3
MASSE
1-2 : rel_standby_com
J13
WARNING_COM
2-3
MASSE
1-2 : rel_warning_com
J3
TC_COM
Not used
1-2 : VD+ / 2-3 : ground
J18
Fault management
in standby mode *
1-2
Decorrelation of standby
mode and faults
-
Inhibition of faults in
standby mode
J19
-
-
J6
RF_INHIB
(interlock)
1-2, 3-4
GROUND
–
GROUND,
serial interlock chain
2-3 : interlock management **
* Working mode when J17 is in position 1-2 (default position).
IF J17 is in position 2-3, reverse jumpers to get the same behavior.
** Routing for J6 in position 2-3: