![Worldcast Systems ECRESO FM 10kW User Manual Download Page 78](http://html1.mh-extra.com/html/worldcast-systems/ecreso-fm-10kw/ecreso-fm-10kw_user-manual_997884078.webp)
ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 78
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
5.19.
Date and Time parameters
These parameters are available as:
Front panel
About/System menu
see section 6.3.24
Serial commands
SYS
see section 7.2.1
Embedded web site
System\Date\Date / Time
see section 8.7.4
DATE and TIME
(SYS.DATE and SYS.TIME)
–
read/write
These parameters set the system date and time. To set the IP board date and time or to synchronize the IP board date
and time with the system date and time, please refer to section 8.7.4.
5.20.
System parameters
These parameters are available as:
Front panel
About/System menu
see section 6.3.24
Serial commands
SYS
see section 7.2.1
Embedded web site
System\Product\Configuration Page
see section 8.7.2
UNIT DISPLAY
(SYS.UNIT)
–
read/write
This parameter sets the input mode for audio silence detection thresholds on all the inputs. With the Relative mode,
level, drive and trim values are given in dBr. In Absolute mode, these values are given in dBu or dBFS and can be
positive. Input levels affect set thresholds; thresholds applied to left and right, and to MPX1 and MPX2 can differ;
however, only left and MPX1 threshold can be set. Default value: RELATIVE.
ABSOLUTE or RELATIVE
CLEAR CONFIGURATION
(SYS.RAZ)
This parameter reset the unit to default configuration.
!
With an IP unit, wait for the IP connection to be available before shutting off the unit.
!
After a configuration reset, we recommend you check parameters meant to protect the transmitter: hard
clipper activation/deviation and VSWR Trip.
DRIVER MANAGEMENT
(SYS.EXC)
–
read/write
As standard, the ECRESO FM 5/10kW includes an Ecreso control unit and one or two Ecreso drivers. This parameter
allows using drivers which are not managed by the control unit. In that case, it needs to be set as external.
The external driver’s
power must be set at 45 W for an Ecreso FM 5kW, and at 90 W for a Ecreso FM 10kW. The
external driver’s frequency must be identical to the Ecreso FM’s frequency.
!
In external mode,
the driver’s RF
must
be enabled before the transmitter’s RF to avoid power o
vershoots.
!
Warning: using an external driver may damage the transmitter.
INTERNAL or EXTERNAL