ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 106
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
NAME
Access
(R/W)
Possible value on the
serial port of the unit
Comments
Module
MEAS.HEAT4
R
±[0..125]
Measures the
heatsink 4
temperature
ECU
MEAS.INT_TEMP
R
0…999
Measure of the temperature of the internal
sensor.
ECU | DRVn
MEAS.LOAD1.TEMP1
R
-
999…999 XXXX
X=[0..9]
Reads the probe1 temperature in load 1 =>
999 when there is no communication, or
probe failed
ECU
MEAS.LOAD1.TEMP2
R
-
999…999 XXXX
X=[0..9]
Reads the probe2 temperature in load 1 =>
999 when there is no communication, or
probe failed
ECU
MEAS.LOAD1.TEMP3
R
-
999…999 XXXX
X=[0..9]
Reads the probe3 temperature in load 1 =>
999 when there is no communication, or
probe failed
ECU
MEAS.LOAD1.TEMP4
R
-
999…999 XXXX
X=[0..9]
Reads the probe4 temperature in load 1 =>
999 when there is no communication, or
probe failed
ECU
MEAS.LOAD2.TEMP1
R
-
999…999 XXXX
X=[0..9]
Reads the probe1 temperature in load 2 =>
999 when there is no communication, or
probe failed
ECU
MEAS.LOAD2.TEMP2
R
-
999…999 XXXX
X=[0..9]
Reads the probe2 temperature in load 2 =>
999 when there is no communication, or
probe failed
ECU
MEAS.LOAD2.TEMP3
R
-
999…999 XXXX
X=[0..9]
Reads the probe3 temperature in load 2 =>
999 when there is no communication, or
probe failed
ECU
MEAS.LOAD2.TEMP4
R
-
999…999 XXXX
X=[0..9]
Reads the probe4 temperature in load 2 =>
999 when there is no communication, or
probe failed
ECU
MEAS.M.PKMAX
R
-
150.0…150.0
Absolute value max of the channel M in kHz
ECU | DRVn
MEAS.MPXPWR.10S
R
-320.00...+320.00
Value of the MPX power over 10 seconds
ECU | DRVn
MEAS.MPXPWR.1M
R
-320.00...+320.00
Value of the MPX power over 1 minute
ECU | DRVn
MEAS.MPXPWR.ATT
R
-320.00...+320.00
Value of the attenuation applied to limit the
MPX power
ECU | DRVn
MEAS.N12V
R
-xx.x x=[0..9]
Measures the -12 V voltage
ECU | DRVn
MEAS.OVDRTRIP
R
xx=[0..9]
Counts amplifier overdrive faults
PAn
MEAS.PCONS
R
[0..9999]
Power used by unit
ECU
MEAS.PFWD
R
[0..9999]
Measure of direct power. examples: "20" or
"300" => 300 W
DRVn | PAn | PSUn
MEAS.PFWD.AVG
R
[0..9999]
Average measured power
ECU
MEAS.PIN
R
[0..99.9]
Measures the input power
DRVn | PAn | PSUn
MEAS.PREF
R
xxx.x x=[0..9]
Measure of reflected power: "20" => 2 W
DRVn | PAn
MEAS.PREFTRIP
R
xx=[0..9]
Counts amplifier reflected power faults
PAn
MEAS.PRESSURE
R
0…2000
Measure of the pressure on the internal
sensor.
ECU | DRVn
MEAS.PSU_TEMP
R
±[0..125]
Measures the temperature of the PSU
DRVn
MEAS.S.PKMAX
R
-
150.0…150.0
Absolute value max of the channel S in kHz
ECU | DRVn
MEAS.SFM
R
[0..125]
SmartFM coefficient to be applied to the set
power
ECU
MEAS.SFN.DELAY
R
0… 5000000.00
Delay applied to the signal in µs
ECU | DRVn
MEAS.SUPPLYTRIP
R
xx=[0..9]
Counts amplifier current faults
PAn
MEAS.TEMPTRIP
R
xx=[0..9]
Counts amplifier temperature faults
PAn
MEAS.VOLT1
R
xxx.x x=[0..9]
Measures the power supply 1 voltage.
Example: "48.0" =>48.0 V
DRVn | PAn | PSUn
MEAS.VOLT2
R
xxx.x x=[0..9]
Measures the power supply 2 voltage.
Example: "48.0" =>48.0 V
PAn | PSUn