Re-assemble the facia assembly in the reverse order ensuring
that the control knobs are correctly aligned.
32. Facia Mounted Programmer.
See Figs. 8 and 12.
Check that the electricity supply to the appliance is turned off.
Remove the cabinet front panel, place the facia and control box
in the Service Position as described in Section 14.2 a and b.
Remove the facia as described in Section 15.1.
Unplug the programmer from the control board from terminals
marked
X2
“Programmer/Switch”. Undo the four nuts securing
the programmer to the facia and remove. Fit a new programmer
in the reverse order and connect the plug at the driver board.
Reassemble the facia in the reverse order.
33. Remote Mounted Programmer.
See Fig. 11.
Check that the electricity has been turned off and isolate the
programmer.
Disconnect the leads from the programmer noting the
alignment. Fit the replacement programmer and reconnect the
leads checking that they are correctly positioned.
33
Fig. 40. Control Board.
1.
Facia panel
2.
Control board
3.
Control board fixing screws (6)
4.
Light guide
5. Temperature control knobs
3
2
1
4
5