35
HW programme ON
HW temperature control
ON
(NO DHW demand)
230V
mains
supply to the
boiler.
Green
power
light ON.
STANDBY
Maximum
heat input
until tank
temperature
3°C below set
point then
80% heat
input.
Tank 1°C
above set
point
OR
Primary
temperature
above 89°C.
Ignition
sequence at
minimum
heat input.
Pump ON.
TANK MODE
AND
CONTROL PRIORITY
Pump continues for
3 seconds.
Pump pulse for 3
seconds if primary
temperature is
above 82°C.
Minimum heat input
if primary
temperature is over
82°C or HW flow
1 to 2.7 l/min.
Tank 8°C
below set
temperature
Primary
temperature
below 90°C.
AND
Gas valve
OFF.
Modulate gas
to set point
(65-75°).
PUMP ONLY
HW temperature control ON
& Draw-off over 2.7 l/min.
HW temperature control ON
& HW programme ON
& Draw-off over 2.7 l/min.
HW temperature control ON &
& HW programme ON
& Tank 8°c below set point.
CH temperature control ON &
& CH programme ON
& Room thermostat demand
OR
CH programme ON
& External frost thermostat demand.
Primary temperature
over 80°C.
Primary temperature
below 5°C.
DHW MODE
TANK MODE
CH MODE
10 SECOND PUMP PULSE INTO CH
SHORT CH MODE (AUTOFROST MODE)