Manual 26694
2301E-ST
Woodward
8
Nippon Kaiji Kyokai:
Requirements specified in Chapter 1, Part 7 of Guidance for the approval
and Type Approval of materials and equipment for Marine use and
relevant Society’s Rules.
RINA
Rules for the Classification of Ships – Part C_Machinery, Systems and
Fire Protection. Ch. 3, Sect. 6, Table 1.
Other International Compliance
Australia &
New Zealand:
Compliance is limited to application for those units bearing the Regulatory
Compliance Mark (RCM) or used in applications where only EMC is
applicable, such as “Fixed Installations” where the RCM & a DoC are not
required.
EMC:
The Electromagnetic Compatibility (EMC) portion of RCM Declaration for
the Australian Radio Communications Act (with applicable amendments)
is a separate document only created for marked products. The products
with RCM on the label have a DoC available, but all products comply with
CISPR11 Group 1 Class A emissions per EN/IEC 61000-6-4 via
Electromagnetic Interference (EMI) testing. This product is part of “Fixed
Installations”.
Special Conditions for Safe Use:
The control must be installed in a suitable enclosure. The final combination must be approved by the local
authority having jurisdiction.
Connect the ground terminal to earth ground.
Use supply wire rated for minimum 75 °C
Use signal wire rated for a minimum of 240 Vac.
Per EN 60079-15:2010: Device meets ATEX Zone 2 requirements when installed in an ATEX
compliant IP54 or better enclosure.
T3 when the Potential Transformer input is 240 Vac
T4 when the Potential Transformer input is 120 Vac
EXPLOSION HAZARD—Do not remove covers or connect/disconnect
electrical connectors unless power has been switched off or the area
is known to be non-hazardous.
Substitution of components may impair suitability for Class I,
Division 2.
RISQUE D’EXPLOSION—Ne pas enlever les couvercles, ni
raccorder / débrancher les prises électriques, sans vous en
assurez auparavant que le système a bien été mis hors tension;
ou que vous vous situez bien dans une zone non explosive.
La substitution de composants peut rendre ce matériel
inacceptable pour les emplacements de Classe I, Division 2.
Released
Summary of Contents for 2301E-ST
Page 15: ...Manual 26694 2301E ST Woodward 13 Figure 2 1a 2301E ST Outline Drawing 8273 1013 1014 Released...
Page 17: ...Manual 26694 2301E ST Woodward 15 Figure 2 2a 2301E ST Plant Wiring Diagram sheet 1 Released...
Page 18: ...Manual 26694 2301E ST Woodward 16 Figure 2 2b 2301E ST Plant Wiring Diagram sheet 2 Released...
Page 19: ...Manual 26694 2301E ST Woodward 17 Figure 2 2c 2301E ST Plant Wiring Diagram notes Released...
Page 125: ...Manual 26694 2301E ST Woodward 123 Declarations Released...