Alignment
Blade Guide Spacing
6
6-10
15doc121912
Alignment
5.
Measure the distance from the bed rail to the bottom edge of the tool.
6.
Loosen one set screw at the side of the blade guide assembly.
7.
Use the set screws shown to tilt the blade guide until the measurement from the bed rail to the tool equals
the first measurement taken at the center of the tool.
See Figure 6-12.
8.
Move the carriage forward so the back end of the tool is over the bed rail.
9.
Use the set screws shown to adjust the blade guide tilt until the measurement from the bed rail to the tool
equals the other two measurements taken.
10.
Move the tool close to the other blade guide and repeat the previous steps.
NOTE:
If major adjustments to blade guide tilt were made, remeasure the distance between the blade and
the bed rails to ensure the correct 1/4" (6.5 mm) blade guide deflection. Adjust if necessary.
6.9
Blade Guide Spacing
HINT:
When adjusting blade guide spacing, loosen the top set screw and one side set screw only. This will
insure horizontal and vertical tilt adjustments are maintained when the set screws are retightened.
1.
Adjust the inner blade guide so the blade guide flange is approximately 1/16" - 1/8" (1.5 - 3.0 mm) from the
back of the blade.
2.
Loosen one side and one top set screw shown. Tap the blade guide forward or backward until properly
positioned.
FIG. 6-12
SM0070
Loosen jam nuts and turn screws
to tilt roller up or down
Loosen jam nuts and turn screws
to tilt roller up or down