SETWORKS OPERATION
Setworks Malfunction
4
4-7
EGdoc031621
SETWORKS OPERATION
4.4
Setworks Malfunction
PROBLEM
CAUSE
SOLUTION
Setworks does not work.
When performing a program,
the controller disengages the
drive mechanism and the
display shows:
When performing the
auto-calibration, the
controller disengages the
drive mechanism and the
display shows:
Magnet sensor improperly
adjusted
Adjust the magnet sensor as
shown in the figures 4-5 and 4-6.
Calibrate the controller -
Enter the real distance between
the blades.
Setworks calculates
dimensions incorrectly.
Improper input parameters
Check the input divider.
Setting the input divider (entered
only once, at the first start-up) and
See Entering the real blade
distance).
- Perform the auto-calibration
procedure.
The blades do not stop after
reaching the preset distance,
but continue their movement
until the limit switch is
activated.
Controller not calibrated
Check the input divider. Perform
the auto-calibration procedure
.
Setworks stops.
Improper signal of the blade
distance sensor.
- Check the connections between
the sensor and the controller.
- Check if the sensor or the
magnetic strip is not loose.
- Check if the connections to the
blade setting system contactors
are correct and not loose.
During manual blade
movement, the upper display
shows a negative value.
Setworks not calibrated
Perform the auto-calibration
procedure
.