SPECIFICATIONS
Sawdust Exhaust System Specifications
Specifications
EGdoc031621
6-4
6
6.3
Sawdust Exhaust System Specifications
See Table 6-5
See the table below for specifications of a sawdust exhaust system that can be used
with the EG350 edger
1
.
TABLE 6-5
IMPORTANT!
The sawdust exhaust system hoses must be grounded or
made with materials not accumulating electrostatic charge.
CAUTION!
Always connect and turn on the sawdust exhaust system
before starting the machine.
Airflow
1200 m
3
/h
Inlet Diameter
150 mm
Motor Power
1.5 kW
Number of Sacks
2 pcs
Sack Capacity
0.25 m
3
Pressure Drop
1.5 kPa (0.22
psi)
1
1
The pressure drop between the inlet of the capture device and
the connection to the CADES should not exceed 1.5 kPa
(for the nominal air flow rate). If the pressure drop exceeds
1.5 kPa the machine might not be compatible with
conventional CADES.
Weight
110 kg
Recommended Conveying Air
Velocity in the Duct
20 m/s
1. External chip and dust extraction equipment with fixed installations are dealt with in
EN12779:2016-04.
!