Maintenance & Alignment
Safety Devices Inspection (Only CE Version)
5
5-15
EGdoc031621
Maintenance & Alignment
The main motor should stop;
Try to start the motor using the START button. It should not be possible to start the motor.
Close the blade housing;
The motor should remain turned off.
4. Maximum Blade Distance Limit Switch
Press and hold the LEFT ARROW button on the control box until the blades stop moving out.
Repeat the above step using the key located on the Setworks controller.
5. Minimum Blade Distance Limit Switch
Press and hold the RIGHT ARROW button on the control box until the blades stop moving in.
Repeat the above step using the key located on the Setworks controller.
FIG. 5-16
Blade Housing
Safety Switch