Maintenance & Alignment
Safety Devices Inspection (Only CE Version)
Maintenance & Alignment
EGdoc031621
5-16
5
6. Anti-Kickback System Limit Switch - Circuit Inspection (2 Persons)
See Figure 5-17
Start the main motor;
Push up the anti-kickback lever lock (A);
Raise the anti-kickback fingers by pushing the anti-kickback lever (B) down;
The main motor should stop;
With the anti-kickback fingers in the up position, try to start the motor using the START button.
It should not be possible to start the motor.
Lower the anti-kickback fingers to their working position.
FIG. 5-17
A