background image

P/N : 388087140

PRINTED IN KOREA

Rapport 

III

Multi Functional CCTV Tester

RAPPORT III / Rev.01/1   Nov.2010

 

99 Washington Street 
Melrose, MA 02176 
Phone 781-665-1400
Toll Free 1-800-517-8431

 

Visit us at www.TestEquipmentDepot.com

Summary of Contents for Rapport III

Page 1: ...7140 PRINTED IN KOREA Rapport III MultiFunctionalCCTVTester RAPPORT III Rev 01 1 Nov 2010 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ...on Major functions of Rapport III Standard item Introduction Product Specification General specification Meter sepecification Functional Specification Power ON OFF Mode setup Video tester DVR function Digital multimeter PTZ controller UTP cable tester 4 5 6 10 10 11 12 18 18 19 20 20 21 22 25 34 38 41 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 3: ...Introduction to the Rapport III explains the available features and appearance Specifications of the Rapport III explains the specification of the Rapport III Functional Use details the functions of the Rapport III and explains their uses General General Rapport III is a Portable Service Monitor Multimeter with a built in 3 5 inch digital monitor It s a simple and convenient multi functional measu...

Page 4: ...and could result in damage to the device MONITOR 5 VOLT DC POWER SUPPLIES COM Precautions Place fingers behind the protecting pad when using a test probe Turn off the power to the circuit under test and discharge all high voltage capacitance before starting resistance or continuity tests to avoid damage to the Rapport III When using the meter function do not forget to turn on the power to the Rapp...

Page 5: ...nt temperatures above 40ºC 104ºF Never short circuit the positive and negative poles of the battery Do not disassemble the battery is not a serviceable item Keep away from static electronic fields while using charging or when storing Stop charging immediately if the battery is overheating emitting a burning smell changed in colour or distorted Only use the supplied battery charger or one with a sa...

Page 6: ...short circuits Video signal generator Mode It outputs a Colour Bar which allows the engineer to test a video monitor or DVR Rapport III supports both PAL NTSC video signal format PTZ Protocol Analyzer It determines which protocol controls a PTZ camera from a PTZ Controller or DVR This helps the CCTV Installer to understand the protocol and find faulty devices Standard Items Check the contents of y...

Page 7: ...the same basic functions but the Rapport III does not include the DVR function On charging RED LED ON Fully charged GREEN LED ON The LED turns Red or Green depend on the recharging status When operating the Rapport without an adapter On operating RED LED ON Low battery RED LED flickers on and off Charging mode Operating mode Power LED Remark Item RED LED Charging Fully charged Charging error Opera...

Page 8: ...ance ve FILE REC PLAY Test Lead Connection FILE MODE SET TELE WIDE OSD PWR CLEAR AC DC V OPEN CLOSE REC PLAY COM V PRODUCT INTRODUCTION Rapport III Pro Part Name Function LCD TFT LCD POWER Red LED is on when the OSD POWER is on Data Transmitting LED Red LED is on when Data is Transmitted Data Receiving LED Red LED is on when Data is Received Key Button Key Button For Controlling External Devices i...

Page 9: ...Function Input BNC Input for External Video signal Output BNC Outputs the Screen Displayed on the Rapport III or the Internally Generated Video Test Signals Communication Port Connections for RS422 and RS485 Input Output Rx RX TX Tx Safety Strap Used to Carry the Rapport III Safely 16 MULTI FUNCTIONAL CCTV TESTER 17 MULTI FUNCTIONAL CCTV TESTER PRODUCT INTRODUCTION PRODUCT INTRODUCTION ...

Page 10: ...00 Electrical Characteristics Input Voltage 12V 10 above 1 2A Battery Lithium Polymer Battery Inner packaging Built in Charger Charging Time More than 6 hrs Operation Time More than 6 hrs Max 8hrs Image TV Type NTSC PAL Image level 1Vpp 140 IRE PTZ Operation Test Protocol Multi Transmission Transmission Speed Mode RS 422 RS 485 2400bps 115 2Kbps UTP Cable Test Tests Continuity Crossed Cable and Br...

Page 11: ...he product After switching the power switch to the ON position press the OSD button and the Rapport III will boot up To turn the Rapport III OFF keep the OSD button depressed for at least 2 seconds and wait until a POWER OFF message is displayed on the Main Screen Release the OSD button and turn off the ON OFF slider switch power is now turned off If the battery indication shows less than you need...

Page 12: ...al as the Video Level The Sync signal is embedded between the Luminance and Colour Burst signals See the following chart for a description of the levels that are expected Indicates that the Rapport III is in video test mode Whenever there is a video input in video test mode the video level is automatically displayed On PAL mode the video will be displayed in IRE On NTSC mode the video will be disp...

Page 13: ...vels that are too low will result in a dim picture with reduced dynamic range A Video Level that is too high will result in washed out pictures with decreased definition The Sync Level controls the drawing of each line on the monitor Sync Levels that are too low will cause the picture to breakup or roll while Sync Levels that are too high will result in a picture with reduced grey colours and dyna...

Page 14: ... move to another mode and remove it Lock SD card When the SD card is locked recording and playback functions are not supported C DVR NTSC FILE 1 EMPTY SD CARD IN SD CARD OUT SD CARD LOCK REC SET MODE MODE MODE C DVR NTSC FILE 2 IN SD MODE C DVR NTSC FILE 2 IN SD REC 00 00 MODE C DVR NTSC FILE 2 IN SD MODE UPDATE FILE 2 YES NO FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION Designate the file sto...

Page 15: ... File C DVR NTSC SD CARD FILE INFORMATION Shows the SD Card files and their recorded file size C DVR NTSC FILE 2 IN SD MODE C DVR NTSC FILE 2 IN SD MODE C DVR NTSC FILE 2 IN SD MODE MODE C DVR NTSC FILE 2 IN SD MODE CLEAR FILE 2 YES NO FILE1 12MB FILE5 FILE2 19MB FILE6 FILE3 FILE7 FILE4 FILE8 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION Press button is shown on the LCD Screen with a Clear Fil...

Page 16: ...e T Ethernet Select language click NEXT Setup the program License Select agree Setup Complete click Finish button Setup Status 3 Installation Setup 2 Supported O S Windows 2000 Professional Windows XP Professional Windows XP Home Edition Windows 2000 Server Windows VISTA Windows 7 32 bit only FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION How to playback the video file on a PC Supported PC spec...

Page 17: ...is off before inserting the SD Card The SD Card label should be on the reverse side when inserted into the Rapport III Pro The SD Card could be damaged if incorrectly inserted SD FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION You will find the icon on your PC desktop after program set up Click the icon and AKR Play Screen starts Click the icon and find the video file you want Test Equipment Dep...

Page 18: ...ntinuity can be tested To prevent electric shocks injury or damage to the Rapport III disconnect the power supply to the circuit under test and discharge all high voltage capacitors before testing resistance and continuity When using the meter function of the Rapport III make sure the unit is switched on and set to the appropriate test mode before connecting the test lead set to the circuit under ...

Page 19: ...Resistance Voltage is the difference in electrical potential between two points The polarity of an AC voltage varies with time while DC polarity is constant The meter displays AC voltage as RMS values root mean square readings The RMS value is the equivalent DC voltage measured in a time varying sinusoidal signal How to measure Press the voltage measuring button and then select AC or DC by pressin...

Page 20: ...ew and press the key and use keys to place the cursor at the location of the chosen preset Then set up the address where the preset is to be stored by using the keys and press the key once more The location information is now stored as a preset address FUNC Follows the FUNC set up using the SPST and MENU information The Setup range is from 00 to 63 It can be set by 1 1 step by using keys SPD SPEED...

Page 21: ...the cable under test is checked by pressing the key Straight through and crossed cables can be verified Disconnections and short circuits are also displayed Connect the UTP cable to be tested to the UTP port of the Rapport III and connect the other end of the cable to the yellow UTP test dongle FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION Short circuit Disconnection Straight cable Cross cable...

Page 22: ... rick of electronic shock Caution hot surface IRE 60417 5031 Reference IRE 60417 5032 IRE 60417 5033 IRE 60417 5017 IRE 60417 5019 IRE 60417 5020 IRE 60417 5021 IRE 60417 5007 IRE 60417 5008 IRE 60417 5172 IRE 60417 5041 The equipment shall not be used for measurements of categories II III and IV If the equipment is used in a manner not specified by the manufacturer the protection provided by the ...

Page 23: ...44 MULTI FUNCTIONAL CCTV TESTER 45 MULTI FUNCTIONAL CCTV TESTER MEMO DRAWING mm Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Reviews: