![WoMaster WR302G Series User Manual Download Page 38](http://html1.mh-extra.com/html/womaster/wr302g-series/wr302g-series_user-manual_994011038.webp)
38
delimiters are matched. When the Flush Time is expired the data will be
sent.
The other section from this Serial page is TCP Server Mode Config. This page allows user to configure the basic
settings of TCP Server Mode.
The description of the columns is as below:
TERMS
DESCRIPTION
TCP Port
Default: Serial 1 – 4000, Serial 2 - 4002
Assign the available TCP port number. The port number of TCP
Server and TCP Client should be the same.
Max Connection
Configures the maximum connection number from 1 to 5.
Idle Timeout (sec)
When serial port stops data transmission for a defined period of
time (Idle Timeout), the connection will be closed and the port
will be freed and re-try for connection with other hosts. Zero is
disabled this setting (default). If Multilink is configured, only the
first host connection is effective for this setting.
Alive Check (sec)
The device will send a TCP alive check package in each defined
time interval (Alive Check) to remote host to test the TCP
connection. If the TCP connection is not alive, the connection
will be closed and the port will be freed for other hosts. If user
sets it as zero, it means disable this setting.