![WoMaster WR302G Series User Manual Download Page 32](http://html1.mh-extra.com/html/womaster/wr302g-series/wr302g-series_user-manual_994011032.webp)
32
Outgoing Rate Limit
Default: 1024000 kbit/s
Set the maximum outgoing rate.
Outgoing Burst
Default: 20 kBytes
Set the maximum outgoing burst.
Click on
Submit
to apply the configuration.
3.3 REDUNDANCY
Redundancy role of the network is to help protect critical links against failure, protects against network loops, and
keeps network downtime at a minimum. Sustainable, uninterrupted data communication network is critical for
industrial applications. Network Redundancy allows user to set up redundant loops in the network to provide a
backup data transmission route in the event that a cable is inadvertently disconnected or damaged. This switch
supports Spanning Tree Protocol (STP) and Rapid Spanning Tree Protocol (RSTP). This is a particularly important
feature for industrial applications, since it could take several minutes to locate the disconnected or severed cable.
3.3.1 RSTP STATUS
This page allows user to see the information of the root switch and port status.
Root Information:
User can see root Address, Root Priority, Root Port, Root Path Cost and the Max Age, Hello Time
and Forward Delay of BPDU sent from the root switch.
Port Information:
User can see port number, port Role, Port State, Path Cost and Port Priority.