Controls / Operation
CT Hoods and DD Ventilation
3-2
Wolf ventilation hoods utilize a 6 button control panel with
LED indicators, that is mounted along the right front edge
of the unit. (See Figure 1)
The
LIGHT
button turns the halogen lights on and off,
and allows the user to choose from three lighting levels,
high, medium and low.
The
HIGH
,
MEDIUM
and
LOW
buttons control the op-
erational speed of the remote or internal blower. An LED
indicator below the button indicates the speed of blower
operation.
To turn the blower off, depress the button over the illumi-
nated LED.
The
DELAY
button activates the delay feature which
allows the blower to continue running at the selected
speed for programmed time period after the button is
depressed.
When in Delay mode both the Delay LED and the corre-
sponding blower speed LED will be illuminated.
If the blower is on high speed when the Delay mode is
activated, the blower will continue to run at high speed
for 5 minutes. The blower will then run at low speed for 5
minutes before turning off.
If the blower is on medium speed when the Delay mode
is activated, the blower will continue to run at medium
speed for 5 minutes. The blower will then run at low
speed for 5 minutes before turning off.
If the blower is on low speed when the Delay mode is
activated, the blower will continue to run at low speed for
5 minutes and then turn off.
If the
DELAY
button is depressed when the blower is off,
no action will take place.
If the
DELAY
button is pressed when the unit is already
in delay mode, the delay mode will be cancelled.
The
FILTER
button monitors the use of the hood. After
30 hours of use at medium speed the Filter LED will
illuminate. The fi lters should be removed and cleaned.
Depress the Filter button to reset the Filter clean LED.
H
EAT
S
ENTRY
M
ODE
Heat Sentry Mode is always in wait and is activated
when exhaust temperature from hood reaches 206 F
(97 C). When this temperature is reached the blower
motor speed will automatically adjust to the next high-
est speed or turn on if the blower motor was off. The
LED of the corresponding blower speed will fl ash on
and off to indicate Heat Sentry Mode.
Once in Heat Sentry Mode, the hood will continue to
monitor exhaust temperatures every three minutes. If
exhaust temperature is at or exceeds 206F (97C) blow-
er speed will be increased to the next highest speed
and the corresponding LED will begin to fl ash. If after
three minutes the exhaust temperature falls below 174F
(79C), blower speed will decrease to the next lowest
speed. If the blower was off prior to Heat Sentry Mode,
the unit will turn off when exiting Heat Sentry Mode.
When blower speed returns to original setting prior to
Heat Sentry Mode activation, the corresponding LED
will stop fl ashing and remain constant.
FIL
TER
HIGH
MEDIUM
LOW
DELA
Y
LIGHT
Figure 3-1 Controls (Wall and Island Hoods)
LED Indicators
E
LECTRONIC
C
ONTROL
FOR
CT H
OODS
Summary of Contents for CT
Page 2: ......
Page 3: ...1 1 General Information CT Hoods and DD Ventilation SECTION 1 GENERAL INFORMATION ...
Page 8: ...1 6 General Information CT Hoods and DD Ventilation NOTES ...
Page 9: ...2 1 Installation Information CT Hoods and DD Ventilation SECTION 2 INSTALLATION INFORMATION ...
Page 35: ...Controls Operation CT Hoods and DD Ventilation 3 1 SECTION 3 CONTROLS OPERATION ...
Page 39: ...Access Removal CT Hoods and DD Ventilation 4 1 SECTION 4 COMPONENT ACCESS REMOVAL ...
Page 54: ...Access Removal CT Hoods and DD Ventilation 4 16 NOTES ...
Page 55: ...5 1 Troubleshooting CT Hoods and DD Ventilation SECTION 5 TROUBLESHOOTING ...
Page 62: ...5 8 Troubleshooting CT Hoods and DD Ventilation NOTES ...
Page 63: ...6 1 Technical Data CT Hoods and DD Ventilation SECTION 6 TECHNICAL DATA ...
Page 66: ...6 4 Technical Data CT Hoods and DD Ventilation NOTES ...
Page 67: ...Wiring Schematics CT Hoods and DD Ventilation 7 1 SECTION 7 WIRING DIAGRAMS SCHEMATICS ...
Page 68: ...Wiring Schematics CT Hoods and DD Ventilation 7 2 MODEL CTWH30 WIRING DIAGRAM ...
Page 69: ...Wiring Schematics CT Hoods and DD Ventilation 7 3 MODEL CTWH36 WIRING DIAGRAM ...
Page 70: ...Wiring Schematics CT Hoods and DD Ventilation 7 4 MODEL IH4227 WIRING DIAGRAM ...
Page 72: ...Wiring Schematics CT Hoods and DD Ventilation 7 6 MODEL DD30 DD36 SCHEMATIC ...
Page 76: ...Wiring Schematics CT Hoods and DD Ventilation 7 10 MODEL DD30 DD36 CONTROL SCHEMATIC ...
Page 77: ...Wiring Schematics CT Hoods and DD Ventilation 7 11 MODEL DD POWER SUPPLY WIRING ...
Page 80: ...Wiring Schematics CT Hoods and DD Ventilation 7 14 BLOWER SCHEMATIC 600 900EXT ...
Page 81: ...Wiring Schematics CT Hoods and DD Ventilation 7 15 BLOWER SCHEMATIC 1200EXT ...
Page 82: ...Wiring Schematics CT Hoods and DD Ventilation 7 16 BLOWER SCHEMATIC 1500EXT ...
Page 83: ...8 1 Parts Exploded CT Hoods and DD Ventilation SECTION 8 PARTS LISTS EXPLODED VIEWS ...
Page 98: ...8 16 Parts Exploded CT Hoods and DD Ventilation NOTES ...