Access & Removal
CT Hoods and DD Ventilation
4-6
T
RANSFORMER
R
EMOVAL
NOTE:
Refer to all WARNINGS and CAUTIONS at be-
ginning of this section.
To access the transformer the lower section of the tele-
scoping chimney fl ue must be raised off of the hood and
temporarily secured in place. The transformer is located
on the top right side of the hood frame and is secured to
the hood with screws.
To replace the transformer, (See Figure 9 & 10):
Raise lower section of chimney fl ue off of hood frame
1.
and temporarily secure in position.
Extract screws securing the transformer wire cover to
2.
transformer and remove from unit.
With a fl at bladed screwdriver, loosen set screws se-
3.
curing wires to transformer terminals. Pull wire leads
out of transformer.
Extract screw from front of transformer. Slide trans-
4.
former out from under mounting bracket.
F
USE
R
EMOVAL
NOTE:
Electrical shock hazard. Refer to WARNING at
beginning of section.
To access the fuse the lower section of the telescoping
chimney fl ue must be raised off of the hood and tempo-
rarily secured in place. The control box is located on the
upper right side of the hood frame. The fuse is located in
a fuse holder inside the control box.
To remove the fuse,
Raise lower section of chimney fl ue off of hood frame
1.
and temporarily secure in position.
Extract screws
2.
securing the control panel cover
to control box and remove cover. (See Figure 11)
Grasp top section of fuse holder with fi ngers and
3.
turn counterclockwise. Pull cap and fuse out of fuse
holder. (See Figure 12)
Figure 4-9 Transformer Removal
Figure 4-12 Fuse Removal
Figure 4-11 Control Box Cover Removal
Figure 4-10 Disconnect Wire Harness
Control Box
Cover
Wire
Cover
Screws
Mounting Screw
Fuse Holder
TO AVOID ELECTRIC SHOCK, POWER TO THE
VENTILATION UNIT MUST BE DISCONNECTED
WHENEVER PERFORMING THE FOLLOWING
REPAIRS.
Summary of Contents for CT
Page 2: ......
Page 3: ...1 1 General Information CT Hoods and DD Ventilation SECTION 1 GENERAL INFORMATION ...
Page 8: ...1 6 General Information CT Hoods and DD Ventilation NOTES ...
Page 9: ...2 1 Installation Information CT Hoods and DD Ventilation SECTION 2 INSTALLATION INFORMATION ...
Page 35: ...Controls Operation CT Hoods and DD Ventilation 3 1 SECTION 3 CONTROLS OPERATION ...
Page 39: ...Access Removal CT Hoods and DD Ventilation 4 1 SECTION 4 COMPONENT ACCESS REMOVAL ...
Page 54: ...Access Removal CT Hoods and DD Ventilation 4 16 NOTES ...
Page 55: ...5 1 Troubleshooting CT Hoods and DD Ventilation SECTION 5 TROUBLESHOOTING ...
Page 62: ...5 8 Troubleshooting CT Hoods and DD Ventilation NOTES ...
Page 63: ...6 1 Technical Data CT Hoods and DD Ventilation SECTION 6 TECHNICAL DATA ...
Page 66: ...6 4 Technical Data CT Hoods and DD Ventilation NOTES ...
Page 67: ...Wiring Schematics CT Hoods and DD Ventilation 7 1 SECTION 7 WIRING DIAGRAMS SCHEMATICS ...
Page 68: ...Wiring Schematics CT Hoods and DD Ventilation 7 2 MODEL CTWH30 WIRING DIAGRAM ...
Page 69: ...Wiring Schematics CT Hoods and DD Ventilation 7 3 MODEL CTWH36 WIRING DIAGRAM ...
Page 70: ...Wiring Schematics CT Hoods and DD Ventilation 7 4 MODEL IH4227 WIRING DIAGRAM ...
Page 72: ...Wiring Schematics CT Hoods and DD Ventilation 7 6 MODEL DD30 DD36 SCHEMATIC ...
Page 76: ...Wiring Schematics CT Hoods and DD Ventilation 7 10 MODEL DD30 DD36 CONTROL SCHEMATIC ...
Page 77: ...Wiring Schematics CT Hoods and DD Ventilation 7 11 MODEL DD POWER SUPPLY WIRING ...
Page 80: ...Wiring Schematics CT Hoods and DD Ventilation 7 14 BLOWER SCHEMATIC 600 900EXT ...
Page 81: ...Wiring Schematics CT Hoods and DD Ventilation 7 15 BLOWER SCHEMATIC 1200EXT ...
Page 82: ...Wiring Schematics CT Hoods and DD Ventilation 7 16 BLOWER SCHEMATIC 1500EXT ...
Page 83: ...8 1 Parts Exploded CT Hoods and DD Ventilation SECTION 8 PARTS LISTS EXPLODED VIEWS ...
Page 98: ...8 16 Parts Exploded CT Hoods and DD Ventilation NOTES ...