2-26
Installation Information
CT Hoods and DD Ventilation
C
ONNECT
THE
C
ONTROL
M
ODULE
Connect the DIN/RJ45 connector cable to the
1.
backside of the remote-mounted control module.
Connect the other end of the cable to the electrical
2.
connection located on the right side of downdraft
assembly. Make sure that all connections are tight.
Refer to the illustration on the front of the downdraft
3.
for the correct orientation of the DIN connector
during installation into the downdraft assembly.
I
NTERNAL
B
LOWER
W
IRING
Models DD30I, DD36I and DD45I
Since these models come with the Blower already
1.
installed in the unit, there is no special wiring
required.
Plug the power cord of the downdraft into the outlet
2.
and energize the receptacle.
R
EMOTE
B
LOWER
W
IRING
Models DD30R, DD36R and DD45R
NOTE:
The remote blower may not exceed a 6.0 amp rating
NOTE:
Detailed instructions of Remote Blower installation are provided with the blower. Refer to installation
instructions provided with each blower to verify wall or roof cut-outs.
NOTE:
Before turning the power on, make sure the blower is in the “OFF” position. Use wire connectors or wire nuts
approved by UL or C/UL.
Locate the blower so the length of the duct run and number of elbows and transitions are kept to a minimum.
1.
Where possible, blower should be located between wall studs or roof rafters.
2.
Avoid pipes, wires or other ductwork that may be running through the wall.
3.
Be sure that there is enough space for any transitions that may be needed between the blower and the
4.
connecting ductwork.
For best performance, locate transitions nearest the blower.
5.
C
ONNECT
R
EMOTE
B
LOWER
NOTE:
Always refer to blower installation instructions provided with the blower for additional mounting and wiring
instructions.
Run 2-wire plus ground power cable from the remote blower to the electrical box on the remote blower adapter
1.
plate.
Connect the downdraft wiring to the power cable from the remote blower. Wire black to black, white to white and
2.
green to green or bare wire. (See Figure 2-50)
Replace the electrical box cover.
3.
Plug the power cord of the downdraft into the outlet.
4.
I
NSTALL
T
OP
C
OVER
NOTE:
Model DD45 comes with the top cover already installed.
Press the UP/DOWN button on the control module.
1.
Remove shipping brackets from the downdraft chimney.
2.
Align the mounting brackets on the back surface of the top cover with the corner mounting positions on top of
3.
downdraft chimney.
Screw the top cover mounting brackets into the mounting holes on downdraft chimney with the four screws
4.
provided. Make sure that the top cover is secure and runs fl ush with the front edge of the downdraft.
Figure 2-50 Remote Blower Connection
Summary of Contents for CT
Page 2: ......
Page 3: ...1 1 General Information CT Hoods and DD Ventilation SECTION 1 GENERAL INFORMATION ...
Page 8: ...1 6 General Information CT Hoods and DD Ventilation NOTES ...
Page 9: ...2 1 Installation Information CT Hoods and DD Ventilation SECTION 2 INSTALLATION INFORMATION ...
Page 35: ...Controls Operation CT Hoods and DD Ventilation 3 1 SECTION 3 CONTROLS OPERATION ...
Page 39: ...Access Removal CT Hoods and DD Ventilation 4 1 SECTION 4 COMPONENT ACCESS REMOVAL ...
Page 54: ...Access Removal CT Hoods and DD Ventilation 4 16 NOTES ...
Page 55: ...5 1 Troubleshooting CT Hoods and DD Ventilation SECTION 5 TROUBLESHOOTING ...
Page 62: ...5 8 Troubleshooting CT Hoods and DD Ventilation NOTES ...
Page 63: ...6 1 Technical Data CT Hoods and DD Ventilation SECTION 6 TECHNICAL DATA ...
Page 66: ...6 4 Technical Data CT Hoods and DD Ventilation NOTES ...
Page 67: ...Wiring Schematics CT Hoods and DD Ventilation 7 1 SECTION 7 WIRING DIAGRAMS SCHEMATICS ...
Page 68: ...Wiring Schematics CT Hoods and DD Ventilation 7 2 MODEL CTWH30 WIRING DIAGRAM ...
Page 69: ...Wiring Schematics CT Hoods and DD Ventilation 7 3 MODEL CTWH36 WIRING DIAGRAM ...
Page 70: ...Wiring Schematics CT Hoods and DD Ventilation 7 4 MODEL IH4227 WIRING DIAGRAM ...
Page 72: ...Wiring Schematics CT Hoods and DD Ventilation 7 6 MODEL DD30 DD36 SCHEMATIC ...
Page 76: ...Wiring Schematics CT Hoods and DD Ventilation 7 10 MODEL DD30 DD36 CONTROL SCHEMATIC ...
Page 77: ...Wiring Schematics CT Hoods and DD Ventilation 7 11 MODEL DD POWER SUPPLY WIRING ...
Page 80: ...Wiring Schematics CT Hoods and DD Ventilation 7 14 BLOWER SCHEMATIC 600 900EXT ...
Page 81: ...Wiring Schematics CT Hoods and DD Ventilation 7 15 BLOWER SCHEMATIC 1200EXT ...
Page 82: ...Wiring Schematics CT Hoods and DD Ventilation 7 16 BLOWER SCHEMATIC 1500EXT ...
Page 83: ...8 1 Parts Exploded CT Hoods and DD Ventilation SECTION 8 PARTS LISTS EXPLODED VIEWS ...
Page 98: ...8 16 Parts Exploded CT Hoods and DD Ventilation NOTES ...