2-24
Installation Information
CT Hoods and DD Ventilation
TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, THIS VENTILATION HOOD SHOULD ONLY BE
INSTALLED WITH BLOWERS MANUFACTURED BY WOLF APPLIANCE INC. AND SPECIFIED FOR USE WITH
THESE VENTILATION MODELS.
D
OWNDRAFT
B
LOWER
AND
D
UCTING
C
ONSIDERATIONS
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
B
LOWER
C
ONSIDERATIONS
The blower will vary in size and is dictated by
the cooking surface, the volume of air that needs
to be moved and the length of the duct run. A
straight, short duct run with a limited number of
elbows and transitions will allow the downdraft to
perform most effi ciently.
A remote-mounted blower will minimize the
amount of blower noise, but will not eliminate the
noise completely.
NOTE:
Blower options vary with the cooking
surface. For recommendations, refer to the Wolf
Design Guide found on the Wolf website, www.
wolfappliance.com.
D
UCTING
C
ONSIDERATIONS
NOTE:
Always consult a qualifi ed HVAC Engi-
neer for specifi c ducting applications.
NOTE:
Wolf ventilation downdraft systems must
be vented to the outside. Use only rigid metal
ductwork.
Wolf downdraft ventilation systems are designed
for use with 3-1/4”(83) x 10” (254) ductwork for
Models DD30I, DD36I and DD45I, and 3-1/4”(83)
x 14” (356) ductwork for Models DD30R, DD36R
and DD45R. Each can be transitioned to 8” (203)
or 10” (254) round ductwork.
For best performance, 10” (254) round ductwork
is recommended. The downdraft will operate
most effi ciently when the ductwork does not ex-
ceed 40’ (12 m) in equivalent duct length.
Choose the ducting option that allows the short-
est length of ductwork and a minimum number of
elbows and transitions. Check the location of fl oor
joists, wall studs, electrical wiring or plumbing for possible interference with the ductwork.
NOTE:
Use duct tape to seal the connection between the blower outlet and ductwork. Support the weight of the duct-
work is necessary to ensure sealed joints.
A
DJUSTABLE
D
ISCHARGE
Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around fl oor joists and
other obstacles. Three different discharge locations are available with side-to-side adjustment for accurate alignment
of ductwork. (See Figure 2-46)
Figure 2-46 Top View Installation Dimensions
Summary of Contents for CT
Page 2: ......
Page 3: ...1 1 General Information CT Hoods and DD Ventilation SECTION 1 GENERAL INFORMATION ...
Page 8: ...1 6 General Information CT Hoods and DD Ventilation NOTES ...
Page 9: ...2 1 Installation Information CT Hoods and DD Ventilation SECTION 2 INSTALLATION INFORMATION ...
Page 35: ...Controls Operation CT Hoods and DD Ventilation 3 1 SECTION 3 CONTROLS OPERATION ...
Page 39: ...Access Removal CT Hoods and DD Ventilation 4 1 SECTION 4 COMPONENT ACCESS REMOVAL ...
Page 54: ...Access Removal CT Hoods and DD Ventilation 4 16 NOTES ...
Page 55: ...5 1 Troubleshooting CT Hoods and DD Ventilation SECTION 5 TROUBLESHOOTING ...
Page 62: ...5 8 Troubleshooting CT Hoods and DD Ventilation NOTES ...
Page 63: ...6 1 Technical Data CT Hoods and DD Ventilation SECTION 6 TECHNICAL DATA ...
Page 66: ...6 4 Technical Data CT Hoods and DD Ventilation NOTES ...
Page 67: ...Wiring Schematics CT Hoods and DD Ventilation 7 1 SECTION 7 WIRING DIAGRAMS SCHEMATICS ...
Page 68: ...Wiring Schematics CT Hoods and DD Ventilation 7 2 MODEL CTWH30 WIRING DIAGRAM ...
Page 69: ...Wiring Schematics CT Hoods and DD Ventilation 7 3 MODEL CTWH36 WIRING DIAGRAM ...
Page 70: ...Wiring Schematics CT Hoods and DD Ventilation 7 4 MODEL IH4227 WIRING DIAGRAM ...
Page 72: ...Wiring Schematics CT Hoods and DD Ventilation 7 6 MODEL DD30 DD36 SCHEMATIC ...
Page 76: ...Wiring Schematics CT Hoods and DD Ventilation 7 10 MODEL DD30 DD36 CONTROL SCHEMATIC ...
Page 77: ...Wiring Schematics CT Hoods and DD Ventilation 7 11 MODEL DD POWER SUPPLY WIRING ...
Page 80: ...Wiring Schematics CT Hoods and DD Ventilation 7 14 BLOWER SCHEMATIC 600 900EXT ...
Page 81: ...Wiring Schematics CT Hoods and DD Ventilation 7 15 BLOWER SCHEMATIC 1200EXT ...
Page 82: ...Wiring Schematics CT Hoods and DD Ventilation 7 16 BLOWER SCHEMATIC 1500EXT ...
Page 83: ...8 1 Parts Exploded CT Hoods and DD Ventilation SECTION 8 PARTS LISTS EXPLODED VIEWS ...
Page 98: ...8 16 Parts Exploded CT Hoods and DD Ventilation NOTES ...