2-5
Installation Information
CT Hoods and DD Ventilation
B
A
C
D
MINIMUM
FLUE
EXTENSION
Flue Extension
Model
Minimum
Maximum
CTWH30
30
1
/
2
" (775)
48
1
/
2
" (1232)
CTWH36
32
11
/
16
" (830)
50
7
/
8
" (1292)
IH4227
33
9
/
16
" (853)
47
1
/
16
" (1195)
CTEWH30I
CTEWH36(I)
CTEWH45(I)
CTEIH42I
MINIMUM
FLUE
EXTENSION
B
A
C
D
s
d
o
o
H
e
li
f
o
r
P
-
w
o
L
p
o
t
k
o
o
C
s
d
o
o
H
y
e
n
m
i
h
C
p
o
t
k
o
o
C
29
1
/
8
”
(740)
41
1
/
2
”
(1054)
29
1
/
8
”
(740)
41
1
/
2
”
(1054)
29
1
/
8
”
(740)
41
1
/
2
”
(1054)
28
1
/
4
”
(718)
41
1
/
2
”
(1054)
H
OOD
P
LACEMENT
Wolf cooktop wall and island hoods come with a
telescopic chimney fl ue that allows you to reach ceiling
heights of 8’ (2.4m) to 9’ (2.7m) with a fi nished look.
A fl ue extension to accommodate 10’ (3m) ceilings is
available as a sales accessory for cooktop chimney
hoods only.
Installation of the cooktop wall or island hood should be
24” (610) to 30” 762) from the bottom of the hood to the
countertop.
To determine placement of the wall or island hood, you
must calculate the heights of the telescopic chimney
fl ue. Refer to the chart in Figure 2-8 above for the
minimum and maximum fl ue extension for specifi c
hood.
NOTE:
Both sections of the telescopic chimney fl ue
must be installed in order for the chimney to be lifted
for service.
NOTE:
If the height of the upper fl ue section is less
than 1/2” (13), you will need to modify the fl ue to affi x
to the fl ue attachment brackets.
Figure 2-8 Hood Placement Dimensions
C
ALCULATING
C
HIMNEY
F
LUE
H
EIGHT
Measure A (total kitchen height from fi nished fl oor to
1.
fi nished ceiling height).
Measure B (height from fi nished fl oor to countertop).
2.
Determine the desired distance from counter-top to
3.
bottom of hood (C). This dimension must be between
24” (610) and 30” (762).
NOTE:
8’ (2.4m) ceilings may not permit installation of the
wall or island hood at 30” (762) above the countertop.
To calculate the chimney fl ue height (D): D = A – (B
4.
+ C). This dimension must be between the minimum
and maximum fl ue extension for your specifi c hood as
shown in the chart.
H
OOD
P
LACEMENT
Summary of Contents for CT
Page 2: ......
Page 3: ...1 1 General Information CT Hoods and DD Ventilation SECTION 1 GENERAL INFORMATION ...
Page 8: ...1 6 General Information CT Hoods and DD Ventilation NOTES ...
Page 9: ...2 1 Installation Information CT Hoods and DD Ventilation SECTION 2 INSTALLATION INFORMATION ...
Page 35: ...Controls Operation CT Hoods and DD Ventilation 3 1 SECTION 3 CONTROLS OPERATION ...
Page 39: ...Access Removal CT Hoods and DD Ventilation 4 1 SECTION 4 COMPONENT ACCESS REMOVAL ...
Page 54: ...Access Removal CT Hoods and DD Ventilation 4 16 NOTES ...
Page 55: ...5 1 Troubleshooting CT Hoods and DD Ventilation SECTION 5 TROUBLESHOOTING ...
Page 62: ...5 8 Troubleshooting CT Hoods and DD Ventilation NOTES ...
Page 63: ...6 1 Technical Data CT Hoods and DD Ventilation SECTION 6 TECHNICAL DATA ...
Page 66: ...6 4 Technical Data CT Hoods and DD Ventilation NOTES ...
Page 67: ...Wiring Schematics CT Hoods and DD Ventilation 7 1 SECTION 7 WIRING DIAGRAMS SCHEMATICS ...
Page 68: ...Wiring Schematics CT Hoods and DD Ventilation 7 2 MODEL CTWH30 WIRING DIAGRAM ...
Page 69: ...Wiring Schematics CT Hoods and DD Ventilation 7 3 MODEL CTWH36 WIRING DIAGRAM ...
Page 70: ...Wiring Schematics CT Hoods and DD Ventilation 7 4 MODEL IH4227 WIRING DIAGRAM ...
Page 72: ...Wiring Schematics CT Hoods and DD Ventilation 7 6 MODEL DD30 DD36 SCHEMATIC ...
Page 76: ...Wiring Schematics CT Hoods and DD Ventilation 7 10 MODEL DD30 DD36 CONTROL SCHEMATIC ...
Page 77: ...Wiring Schematics CT Hoods and DD Ventilation 7 11 MODEL DD POWER SUPPLY WIRING ...
Page 80: ...Wiring Schematics CT Hoods and DD Ventilation 7 14 BLOWER SCHEMATIC 600 900EXT ...
Page 81: ...Wiring Schematics CT Hoods and DD Ventilation 7 15 BLOWER SCHEMATIC 1200EXT ...
Page 82: ...Wiring Schematics CT Hoods and DD Ventilation 7 16 BLOWER SCHEMATIC 1500EXT ...
Page 83: ...8 1 Parts Exploded CT Hoods and DD Ventilation SECTION 8 PARTS LISTS EXPLODED VIEWS ...
Page 98: ...8 16 Parts Exploded CT Hoods and DD Ventilation NOTES ...