background image

Plakhorstweg 12

NL-7008 AT  DOETINCHEM

t: +31 [0]314-320910

f: +31 [0]314-320919

e: [email protected]

w: www.abk-innovent.nl

All rights reserved [Rev.110610] Art.nr. KDI0100004

Customer service

In  case  of  problems  you  cannot  solve 
yourself,  please  contact  your  supplier 
our  the  ABK  InnoVent  service 
department 

USER | INSTRUCTION MANUAL

i-Cooking 

induction

Read this manual carefully before installing and 
using your i-Cooking induction product, for your 
own safety and to prevent any unnecessary 
damage to the product and/or your kitchen. 

Summary of Contents for i-Cooking

Page 1: ...320910 f 31 0 314 320919 e info abk innovent nl w www abk innovent nl All rights reserved Rev 110610 Art nr KDI0100004 Customer service In case of problems you cannot solve yourself please contact your supplier our the ABK InnoVent service department ...

Page 2: ...CTION MANUAL i Cooking induction Read this manual carefully before installing and using your i Cooking induction product for your own safety and to prevent any unnecessary damage to the product and or your kitchen ...

Page 3: ...EN 2 ...

Page 4: ...ety instructions 08 Chapter 3 3 1 Induction technology 10 3 2 Using the appliance 11 3 3 Display 11 3 4 Cooking functions 12 3 5 Pans 15 Chapter 4 4 1 Maintenance 15 4 2 Helpful tips 16 4 3 Troubleshooter 16 Chapter 5 5 1 Electrical installation 17 5 2 Installation 18 5 3 Configuration 21 CE Declaration 22 EN 3 Contents ...

Page 5: ... suitable for private use only under normal your personal preference For example daily conditions If any failure should arise with more space in between making it weadviseyoutocontactyoursupplier muchmorepracticaltouselargerpans The zones are available in two power ranges up to 3000W both have a boost function With the flush or top mount installation the zones are completely integrated into the wo...

Page 6: ...ponents i Cooking induction example 1 Power zone boost 3100W 2 Standard zone boost 1770W 3 Control panel touch control 4 Power unit loaded rate 3600W to 7200W 2 separate branch circuits 1 2 4 3 EN 5 Components ...

Page 7: ...of fixation flush mount installation top mount installation A B 4 53 C 5 min A 4 53 C description dimensions standard zone power zone control panel Wire code 5 7 C ceramic glass A Ø270mm Ø300mm 276x150 R 75mm rabbet dim B Ø274mm Ø304mm 280x154 R 77mm cut out dim C Ø254mm Ø284mm 260x134 R 67mm glass thickness 4mm 4mm 4mm total height 4 53mm 4 53mm 4 31mm induction zone Ø160mm Ø200mm power 1100W 230...

Page 8: ... disposed properly as quick as possible This product is only for the domestic preparation of food Any other use is 2 1 2Technicalsafety prohibited and may lead to danger The Check the product before any use on manufacturer cannot be held liable for any visible failures In case of doubt do not use damages arisen by incorrect use or any it A damaged product can harm your otheruse safetyandhealth Bef...

Page 9: ...may cause burninginjuriesunexpectedly When using the appliance heat and moist arise Always make sure that the space or Do not heat closed cans etc on the room where the appliance is used is appliance These cans may explode ventilated properly Open a window or because of over pressure possibly take care of a mechanical extraction for causinginjuryorriskoffire examplebya properkitchenextractor Do no...

Page 10: ...eads to expiration of the guarantee and preparing is heated sufficiently Possible productliability present bacteria are only eliminated if the temperature is high enough above 70 C The manufacturer cannot be held liable and is kept so long enough at least 10 for damages resulting from not minutes following the safety instructions and warnings If you use a drawer under the i Cooking appliance witho...

Page 11: ...9 or with a magnetic bottom is placed on the simply by pressing the required position zone itwillheatthepanbottom direclty For this type of cooking specific pans with a thick magnetic bottom are Each induction zone has its individual required The induction zone cooling ventilator which will start blowing automatically adapts itself to the pan at low speed if the zone heats up It will bottom diamet...

Page 12: ...lpanel On off 0 9 Poweradjuster slider U Pandetector nosuitableortoosmallpan A Automaticcooking E Error electronicfailure H Restwarmthindicator P Powerbooster L Lock Warmingfunction 70 C Pauseposition Touchcontroldisplay variespermodel ...

Page 13: ...ates next to the zone lights up as well Now the maximum available power If the adjust the required power To stop adjust power boost is activated this might the power to 0 In the display a 0 or influence the power of another linked H restwarmth symbolappears induction zone This happens when the If nothing is touched the display requested power exceeds the maximum automatically switches into the wai...

Page 14: ...king based on see 00 The number 16 now must be powerposition7 enteredintwosteps first 6 then 1 1 Switch on the appliance by pressing the 5 Move the slider until you see the on offsymbolonthecontrolpanel number 6 Confirm by pressing the timer 2 Select the right zone by pressing the indicator symbol on the control panel 0 and 7 Move the slider until you see the indicatorondisplayislit number 1 and c...

Page 15: ...vidualzones Tounlockagain Automaticcookingsettings 1 Presstheon offswitch Followthesesteps 2 Simultaneously press the P and L of 1 Presstheon offsymbol the right display within 5 seconds The 2 Press the pause symbol within 6 symbol 0 or H appears in the display seconds Now the previous settings are Press the P again and all displays are activated switchedoff 3 4 11Warmingfunction By using this fun...

Page 16: ...or the cooking induction zone Use the following ground zones rule largediameteronapowerzone Never use these products to avoid smalldiameteronastandardzone degradation of the cooking appliance Seeindicativetablebelow surface sand soda alkali acid or chloride containing cleaners grill or oven sprays 3 5 3Energy consious cleaners for dishwashers stain or rest Cook energy consious preferably with a re...

Page 17: ... ventilator protects Theapplianceisnotworking the electronics from overheating After Faulty connection to the electrical cooling down sufficiently the ventilator network willautomaticallystop Afuseorstophasinterfered Thelockfunctionisactivated The automatic cooking function does There is water or grease on the control notwork keys Thecookingzoneisstillhot code H For activation the highest power po...

Page 18: ...or in held liable for direct and or case of a permanent electrical installation indirect damages resulting from an it must be possible to disconnect the inexpert installation or incorrect appliancefrom the electrical network via a connection switch with all polesWanneer het stopcontact niet toegankelijk is of er een Moreover the manufacturer cannot be vaste aansluiting wordt gemaakt dan held liabl...

Page 19: ...reparation of food Any other use is prohibited 4 Remove before use all labels and Important This appliance stickers which are on the ceramic glass needs sufficient ventilaton induction plates Consider this during the installation 5 The induction zones and control panel make sure that the ventilation may not be used as working or storage apertures are in line with the air tops supply apertures in t...

Page 20: ...ookingzones Installationexample For the various installation methods use the brass connectors whic are placed in thepowerunit Attention Alwaysconnecttheearthwire Act in accordance with the wiring diagram which can be found on the power unit Thisappliancecanonlybeusedona 230V 50Hzelectricitynetwork De electrical connections of the power unit are on the underside at the rear Use a screwdrivertoopent...

Page 21: ...itch from 1 on to 0 off 4 Earthleakagecircuitbreaker Turn the main switch from 1 on to 0 off orpressthetestbutton Atttention Make sure that the e l e c t r i c a l t e n s i o n c a n n o t accidentallybeswitchedonagain Recycling The packaging of this appliance can be fully recycled cardboard Ensure a proper disposalofthese If you must dispose the appliance itself please supply it to a specialized...

Page 22: ...r the tension is switched on again zone and wait untill the code C changes Take a pan with a diameter of 16cm do not intocode Thezoneisnowassigned use different pans within the configuration F Repeat the procedure of E to assign the process remaining cooking zones After all zones have been allocated the codes in the Removinganexistingconfiguration displaydissapear A Press the symbol p and keep it ...

Page 23: ...cturer Hereby declares that the i Cooking induction appliance is in conformity with all relevant provisions of the Low Tension Council Directive 2006 95 EC according to the most recent version is in conformity with all relevant provisions of the EMC Council Directive 2004 108 EC according to the most recent version is in conformity with the following harmonised standards Domestic and similar appli...

Page 24: ...EN 23 Notes Notes ...

Reviews: