One or more zones have been switched-
4.2 Helpful tips
off
The safety system may have interefered
Make sure that the pans are positioned in
because:
the middel of the zone while cooking,
-you forgot to switch-off the cooking zone.
because of the automatic pan detection
-one or more switches are covered.
sytem integrated in the zones.
-the pan is empty and the bottom is
overheated.
Repairs to electrical appliances may only
-The appliance also has an automatic
be executed by certified professionals.
power reduction and emergency stop in
Inexpert executed repairs cause danger
case of an overload.
for the user.
Ventilator continues after switching-off
4.3 Troubleshooter
the zone
-This is not an error, the ventilator protects
The appliance is not working
the electronics from overheating. After
-Faulty connection to the electrical
cooling down sufficiently, the ventilator
network.
will automatically stop.
-A fuse or stop has interfered.
-The lock function is activated.
The automatic cooking function does
-There is water or grease on the control
not work
keys.
-The cooking zone is still hot, code ”H“.
-For activation the highest power position
Code ”U”
has been set to ”9”.
-There is no pan placed on the cooking
zone.
On the display I can see 3 or 4 ”L“ codes
-The pan is not suitable for induction
-See chapter 3, lock function is activated.
cooking.
-The pan bottom diameter is too small for
On the display I can see a ”U“code
the zone.
-See chapter 3, warming fucntion is
activated.
Code ”C“ or “E“
-Call your supplier for a repair and clearly
On the display I can see the code ||
mention the error code.
-See chapter 3, pause function is
activated.
EN 16 Troubleshooter
Chapter 5
EN 17 Installation
Rated load:
5.1 Electrical installation
See type plate on your appliance.
The i-Cooking appliance may only be
Connection:
connected to an effectively grounded
AC 230V | 50 Hz
power socket. This power socket must
always remain freely accessible for
Fuse:
possible servicing purposes.
10A [type B or C]
The appliance may only be connected to
the electrical network by a certified
Earth leakage circuit breaker:
electrician. He or she is aware of the
According to EU regulations and
national and local regulations of the power
guidelines, it is advisory to fit the electrical
company. Installation is only allowed on a
house installation with an earth leakage
NEN 1010 certified installation.
circuit breaker [30mA].
The manufacturer cannot be
If the power socket is not accessible, or in
held liable for direct and/or
case of a permanent electrical installation,
indirect damages, resulting from an
it must be possible to disconnect the
inexpert installation or incorrect
appliancefrom the electrical network via a
connection.
switch, with all polesWanneer het
stopcontact niet toegankelijk is of er een
Moreover, the manufacturer cannot be
vaste aansluiting wordt gemaakt, dan
held liable for damages resulting from a
moet de toepassing via een schakelaar,
missing or damaged earth wire [for
met alle polen. The contact distance in
example an electrical hazard].
switched-off condition must be at least
3mm. You can use auto-off switches,
After installation, it must be secured
fuses and relays according to EN 60 335
that parts which are under electrical
regulations.
tension, cannot be touched.
Before installation, the present installation
data of the electrical network must be
compared with those on the type plate
[voltage and frequency]. These data must
be corresponding.
!