821016: AMPx-E8 Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
40
Chapter 3
Audio Configuration
Terminating/Unterminating Inputs
Terminating/Unterminating Inputs
Each of the AES and bitstream inputs on the AMPx-E8 may be
terminated or unterminated independently of each other. A given input
should be terminated when the AMPx-E8 is the last receiving device in
the signal path or is the only receiving device in the signal path. If the
signal loops through the AMPx-E8 to another receiving device, the
input should be unterminated in the AMPx-E8 (and terminated at the
last device in the signal path). Terminating the signals properly
improves signal integrity, and ensures the signal will be received
correctly by all the devices in the signal chain.
In the AMPx-E8 monitors, the terminations are set to “Enabled” by
default for all inputs.
To change the termination settings:
1.
Hold the
Fn
button while pressing the
Setup
button.
2.
Press the
Down
button once. The LCD should look similar to the
image in
Figure 3–14
below.
Figure 3–14
AES Termination Settings
3.
Press the
Enter
key. The LCD should now look like the image
Figure 3–15
or in
Figure 3–16
.
Figure 3–15
Termination Setting Currently Enabled
Figure 3–16
Termination Setting Currently Disabled
848131 2.00
Setup: Aes Term
AES Termination
Unbal. 1: Ena
AES Termination
Unbal. 1: Disa