You can also use
SCP-compatible connection to the router by your computer with an SCP client (like
WinSCP). You can also copy the stored files to a locally mounted uSD drive for data collection or
further data logging, analysis.
The incoming files of the Modbus device are stored here in CSV format by the following syntax in
the CSV file:
• PLC address – meter PLC addres
• STATUS - OK,ERROR, etc.
• timestamp – readout datetime (YYYYMMDDhhmmss)
• *register address N – decimal address
• *register value N – raw data
*The registers are repeating until the end of the data flow
Example: 200,OK,2019-04-29 13:17:14,7,69
The M-Bus configuration in OpenWrt:
You have to use
2019-09-20 or later firmare versions for MBus meter configuration where it is
available.
After the firmware refresh, check the Services menu, mbus menu item at a
t the
MeterList
ta,