3.

 

Insert and push 

an activated

 mini SIM card

 to the 

SIM 1

 titled tray (No. 4), top SIM 

holder. Insert by following the hints of SIM card figure for the proper orientation. (The SIM 
chip-side will be face down and the cutted edge towards to inside and push until it sleeves). 
 

 

 

4.

 

If you are using an LTE450 module 

than you need to insert the SIM card into the bottom 

SIM 2

 tray (No. 5). Orientation: the SIM chip will face up and the SIM title down. 

 

5.

 

You can use the 

micro-USB

 (No. 3) connector with a 

microUSB-to-USB cable connection as 

USB LAN

 - instead of the Ethernet connection. 

 

6.

 

Beside / instead of USB connection you

 can connect 

an 

UTP cable to the LAN1 

(No. 6) 

and/or

 LAN2 

(No. 7), 

LAN3

 (No. 8), 

LAN4 

(No. 9) RJ45 interface Ethernet port.  

 
The other side of the UTP cable must be 

plugged to your computer 

or a network device 

(hub or switch, if you are attempted to use one).  
 
Note, that the Ethernet ports are bridged by default, which means its equal which port you 
are using. 

7.

 

By  default,  the  data  concentrator

 

has  an  installed  OpenWRT

®

  operating  system  which  is 

ready to use and configure to your SIM card APN and for you usage requirements. 
 

8.

 

Plug

 the 

100-230V AC power 

supply to power input

 

terminal block (No. 1), according the 

pinout. 
 

Current / power consumption  

 

Power supply / Voltage range: ~100-230V AC, 50 Hz  

 

Current: 0.1A at ~230V AC 

 

 

Consumption: 3 - 15W 

 
The following cables are not part of the accessories of the delivered package. 

Use the following hints and the recommendation to choose useful cable and type to prepare 
the necessary connection(s) according to your requirements. 

Summary of Contents for M2M PRO4 DCU

Page 1: ...M2M PRO4 DCU Installation Guide v1 70 _________________________________________ 2021 04 12...

Page 2: ...installation steps of the device Document category Installation Guide Document subject M2M PRO4 DCU Author WM Systems LLC Document version No REV 1 70 Number of pages 33 Linux Kernel 4 14 23 OpenWRT s...

Page 3: ...APTER 2 INSTALLING THE DEVICE 15 2 1 The very first startup 15 2 2 Normal startup 16 2 3 Local access via Ethernet 17 2 4 Local access via USB LAN 17 2 5 Web user interface and Login 18 2 6 SSH access...

Page 4: ...ase of presence of the optional LTE450 LTE Cat M Cat NB module 6 Ethernet LAN1 port IEE 802 3 100 10 Mbit FastEthernet full duplex bridged RJ45 connector 7 Ethernet LAN2 port IEE 802 3 100 10 Mbit Fas...

Page 5: ...ther items or devices Any modification and repairation is not allowed without the permission of the manufacturer It all causes the loss of product warranty Only a certified expert or the manufacturer...

Page 6: ...onnect all power before Installing or removing a chassis Working near power supplies Look carefully for possible hazards in your work area such as moist floors ungrounded power extension cables frayed...

Page 7: ...NT SAFETY INSTRUCTIONS This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitr...

Page 8: ...nergize the unit Statement 1028 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warning Ultimate disposal of this product sho...

Page 9: ...IN Rail fixation due its case which is to be intended to mount to DIN 35 rail or using a 3 point fixation by screws or using the hook in hanging position You can also mount the enclosure to wall place...

Page 10: ...e cabinet and placed onto the cabinet s surface to ensure enough reception 1 4 Cabling wiring 1 Remove the plastic transparent port protector No 15 part by releasing the two screws No 14 from the top...

Page 11: ...8 LAN4 No 9 RJ45 interface Ethernet port The other side of the UTP cable must be plugged to your computer or a network device hub or switch if you are attempted to use one Note that the Ethernet ports...

Page 12: ...ble Type Cat5e UTP PVC Connector type RJ45 Ethernet Function RJ45 LAN Ethernet connector to external device RS485 cable Type 2 3x LgY 0 75 mm2m signed by color blanked cables Connector type 3 pins ter...

Page 13: ...ot can be used Please pay attention to the use the SIM2 tray the chip is facing up The IPv6 protocol is disabled for the LAN interfaces by default change it if you want to use it instead of the IPv4 p...

Page 14: ...y on terminal block MBus pins o RS485 connection and activity on on terminal block RS485 pins o WAN wireless network connection and access o USBLAN connection on microUSB port o KERNEL for sign possib...

Page 15: ...not start the data concentrator as usual by adding the AC power supply only because only the PWR led will be active lighing by green but the device won t start further First you must start the data co...

Page 16: ...NB module insert active SIM card into SIM 2 titled tray 3 Mount two antennas to the Antenna interfaces No 12 and 13 4 After plugging the AC Power source No 1 the device begins to perform booting the L...

Page 17: ...c The MBUS RS485 WAN USBLAN leds will be flashing during 30 seconds until boot d At the end of the boot process only the WAN USBLAN leds are flashing for 5 10 seconds...

Page 18: ...will be lighting and the current SIGNAL LEVEL leds will be also lighting its signal strength value which means connected and you have useful wireless signal reception for the usage and data transmitti...

Page 19: ...r for using the USB connection https www m2mserver com m2m downloads USB_Ethernet_RNDIS_DRIVER zip 2 After you ve connected the USB microUSB cable you can add the driver in the Windows Start Control P...

Page 20: ...ault URL is https 192 168 1 1 The USB web interface default URL is https 192 168 10 1 3 Use the Mozilla browser In your browser window you will get a security risk message Ignore the security message...

Page 21: ...5 The OpenWRT system s LuCi web interface has loaded into your browser Now fill the Username and Password fields and click on the Login button for the entry Username root Password wmrpwdM2M...

Page 22: ...or the Ethernet interface LAN1 LAN4 ports or the 192 168 10 1 22 port nr 22 for the USB interface Allow to acccess the device ignore the security breach message in your computer in the pop up window C...

Page 23: ...from the product website https www m2mserver com m2m downloads UCI_Command_Line_Reference_v3 pdf 2 7 Wireless access Before using the wireless access you need to setup the SIM card s current APN prop...

Page 24: ...APN the WAN LED will lighting by green and the SIGNAL LEVEL will be also signed according to the signal reception it is lighing by green If the module with the SIM card was connected the module is im...

Page 25: ...CHARGE No FIXED Supercap Battery is fully charged no need to charge N A Supercap Battery is exhausted and it is currently charging Group B MBUS Yes No Receive Transmit MBus data RS485 Yes No Data flow...

Page 26: ...nnection on ethernet port3 LAN3 Data flow Connection through ethernet port3 LAN4 Yes No connection on ethernet port4 LAN4 Data flow Connection through ethernet port4 2 9 Power On Supercap Charging mod...

Page 27: ...ss only the ON LED will be lighting by green but the PWR LED will be blank When the shutdown process has been finished all LEDs will be inactive Replug power supply Stabilizing the power line In case...

Page 28: ...sec START the device when it was stopped before AND the device has power source the ON led will lighting green 6 sec Power off STOP the device if it was operating all LEDs will inactive only the PWR...

Page 29: ...g red Push the RESET again once for 1sec selected mode 1 restoring default config KERNEL led red is flashing once per second Push the RESET again for 6sec confirm your selection The device will delete...

Page 30: ...s please change the configuration settings and save them The device will be automatically apply your settings When you have logged in at the startup screen Status Overview the web interface can be see...

Page 31: ...connections sessions will be reconnected as the power source estabilished and the network is reachable IP settings 1 By default the Ethernet IP address is static the default IP address is 192 168 1 1...

Page 32: ...rt questions the product identifier is important for resolve your problem Please when you are attempting to tell us an incident please send us the IMEI and SN serial number information from the produc...

Page 33: ...he pictures in the user guide are only for illustration purposes WM Systems LLC does not confirm or accept responsibility for any mistakes in the information contained in the user guide The published...

Reviews: