RC802/804/806-30B-FV35  

V.35 Interface 

Fiber Optic Modem

 

 

 
 
 
 
 
 

User Manual 

(Rev. N) 

 

 
 
 
 
 
 
 
 

 
 

 
 

Raisecom Technology Co., Ltd. 

(05/2006)

 

Summary of Contents for RC802-30B-FV35-S1

Page 1: ...RC802 804 806 30B FV35 V 35 Interface Fiber Optic Modem User Manual Rev N Raisecom Technology Co Ltd 05 2006 ...

Page 2: ...e to Fiber media converter please test the transfer optical power of the latter If the optical power is beyond the overload point of this device please don t connect them otherwise the optical module will be damaged This RC802 804 806 30B FV35 series fiber optic modem is integrated device that has precise elements please avoid violent shakes and impacts and do not disassemble or maintain the devic...

Page 3: ... Setup of Timeslot Dip switch SW1 to SW4 9 3 2 2 Function Dip switch SW5 10 3 2 3 Function Choosing Dip switch SW6 12 3 3 Relationship between dip switch and software configuration 13 3 4 Basic Connection Type 13 3 4 1 Point to point Master Clock Slave Clock Topology 13 3 4 2 Point to point Terminal Clock Slave Clock Topology 14 3 4 3 Extended Connection Type 14 4 Installation preparation 15 4 1 B...

Page 4: ... and maintain device z Support internal E1 data channel s fractional unframed transparent transfer mode It can distribute timeslot freely in fractional mode z Provides three clock mode master clock internal clock slave clock follow fiber line clock V 35 terminal clock follow V 35 interface clock z When use fractional mode in a pair the remote timeslot can follow local timeslot s configuration z In...

Page 5: ...ode DSC 15 120KM RC803 30B FV35 S1 Standalone at the Customer Premises one V 35 interface M 34 Female one optical port single fiber single mode 1310 SC PC 0 25KM RC803 30B FV35 S2 Standalone at the Customer Premises one V 35 interface M 34 Female one optical port single fiber single mode 1310 SC APC 10 50KM RC805 30B FV35 S1 Standalone at the Customer Premises one V 35 interface M 34 Female one op...

Page 6: ...on distance Km RC802 30B FV35 S1 1310 FP PIN 15 8 8 34 0 25 RC802 30B FV35 S2 1310 FP PIN 5 0 8 34 10 60 RC802 30B FV35 S3 1550 DFB PIN 5 0 10 36 15 120 RC804 30B FV35 S1 1310 FP PIN 12 3 8 30 0 25 RC806 30B FV35 S1 1550 DFB PIN 12 3 8 30 0 25 RC804 30B FV35 S2 1310 FP PIN 5 0 8 32 10 50 RC806 30B FV35 S2 1550 DFB PIN 5 0 8 32 10 50 2 3 Cable type When connect this series product with DTE equipmen...

Page 7: ...2 5 Structure character Dimension 91 25 178 W H D mm 2 6 Ambience Working temperature 0 45 Humidity 90 25 non condensing ...

Page 8: ...l has LOS LOF 1 E 3 error code alarm Steady Yellow In fractional mode E1 data channel of local fiber signal has AIS alarm G 704 LOF alarm G 704 multi LOF alarm CRC4 verification error In unframed transparent mode E1 data channel of local fiber signal has AIS alarm Flash Yellow Only occur in frame mode E1 data channel of Remote fiber signal has AIS alarm G 704 LOF alarm G 704 multi LOF alarm CRC4 v...

Page 9: ...O T Receive Timing A RCK A O V Receive Timing B RCK B O X Send Data A TD A I P Send Data B TD B I S Send Timing A TCK A O Y Send Timing B TCK B O AA Terminal Timing A SCTE A I U Terminal Timing B SCTE B I W Request to Send RTS I C Clear to Send CTS O D Data Set Ready DSR O E Data Carrier Detect DCD O F Data Terminal Ready DTR I H 3 2 Dip switch Setup There are six dip switches on the bottom of the...

Page 10: ...d bit 4th bit 5th bit 6th bit 7th bit 8th bit SET TS8 TS9 TS10 TS11 TS12 TS13 TS14 TS15 ON OFF SW3 definition default is all OFF 1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit SET TS16 TS17 TS18 TS19 TS20 TS21 TS22 TS23 ON OFF SW4 definition default is all OFF 1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit SET TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31 ON OFF Notice ...

Page 11: ... interface clock ON ON Slave Clock Follow fiber line clock 2 The 3rd bit Timeslot auto follow function TS_FLOW default OFF SW5 3 Timeslot auto follow function ON Enable OFF Disable To make local timeslot follow remote timeslot below four conditions should be ensured 1 This series device is used point to point in pair 2 There is no PCM device linked in E1 line 3 Two end devices should not work in t...

Page 12: ...back can be realized by fiber but the dual fiber S3 and all single fiber are forbidden At the time when PWR PAT indicator is steady yellow it indicates that correct test code was received If the remote dual direction loop back is enabled accompanied with error code test it means the whole information process will be tested 4 The 5th bit RC CLK Phase choosing dip switch default OFF SW5 5 Phase Choo...

Page 13: ...hen two devices of this series are used in pair if remote device is inserted in RC001 1 single slot chassis it will work on managed by remote device mode automatically but if it is inserted in RC002 16 chassis it must be configured as Force managed by remote device If the device is for local management its SW5 8 must be OFF Notice If two of this using in pair device are both inserted in RC002 16 c...

Page 14: ...rmally 3 The 5th 6th 7th 8th bit Vendor configuration dip switch These bit are configured by producer and please don t change 3 3 Relationship between dip switch and software configuration The corresponding relationship of above device dip switch and network management ability is shown as below table Dip switch The configuration can be changed by software or not SW1 SW4 Can SW5 Can SW6 Can not 3 4...

Page 15: ...k Mode In Terminal Clock Slave Clock topology if DXC MUX devices are in E1 link the DXC MUX and remote modem should all be slave clock mode follow the clock of E1 link RC802 30B FV35 RC801 30B FV35 Fiber Router Router V 35 DTE wire V 35 DTE wire Terminal Clock Slave Clock Clock Source 3 4 3 Extended Connection Type RC802 30B Fiber Router ATM DDN Router V 35 DTE wire E1 E1 cable RC802 30B FV35 If E...

Page 16: ...ave clock mode 4 Installation preparation 4 1 Before installation z Please make sure that the V35 cable you use matches the equipment you want to connect z Please check if the equipment has been destroyed ...

Page 17: ...al bi direction loop back test Refer to previous dip switch setup for details If the Router indicates loop back successful the V 35 interface is working in good condition If the Router indicates loop back fails please first check the timing resource and bandwidth setup at local site and try to adjust the TX CLK and RX CLK phase option switch 2 If the E1 interface of remote equipment is connected w...

Page 18: ... then judge error code status according to PWR PAT indicator z PRI of network management and DIP switch Answer CPU will read the DIP switch configuration once it is powered on and then network management has higher privilege Notice that network management cannot configure Fault Pass Through function z Severe Packet Loss Answer this may be caused by the following conditions There is more than one c...

Page 19: ...pins have no connection Request The cable material is not lower than 80 30V 2 CBL V35 HDB26M M34M X Cable making Instruction This cable is cross connection cable which is used to link the V 35 DCE interface of node equipment as DDN to the V 35 interface of the RC802 30B FV35 series device Using this cable if the clock resource is provided by node equipment the RC802 30B FV35 series device should b...

Page 20: ... SCTE A U 17 RCLK A SCTE B W 25 RCLK B SGND A 1 SGND GND B 7 GND TCLK A Y disconnect 15 TCLK A TCLK B AA disconnect 23 TCLK B DCD F 8 DCD DSR E 6 DSR CTS D 5 CTS RTS C 4 RTS DTR H 20 DTR Other pins have no connection Request The cable material is not lower than 80 30V ...

Page 21: ...BROADBAND to RAISECOM 2005 Raisecom Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification ...